Bosch 8-Dec User Manual
Page 48

40 | Control Panels, Control Centers, and Keypads | 7000 Line
PO 2: can be used with Alarm + as a supervised siren driver.
Connect an approved 4 Ω or 8 Ω speaker. Alternatively, PO 2
can sink up to 500 mA, 12 VDC.
PO 3 and PO 4: can be configured for Alarm Output. These
outputs can sink 500 mA, 12 VDC each.
Certifications and Approvals
Region
Certification
Europe
CE
1999/5/EC, 2006/95/EC, 2004/108/
EC; EN 55022:2006 + A1:2007, Class B;
EN 50130-4 w/A1:1998 + A2:2003;
EN61000-3-2:2006;
EN61000-3-3:1995; EN 60950-1:2001;
TBR21:1998
Russia
GOST
GOST 12997-84, GOST R MEK
60065-2002, GOST R 50009-2000,
GOST R 51317.3.2-99, GOST R
51317.3.3-99
France
AFNOR
NF, A2P (122077-00)
China
CCC
2005031902000137
Sweden
INTYG
Nr05-303
Brazil
ANATEL
1240-05-1855
The DS7220V2 Control Panel is designed to comply with the following cer-
tifications, approvals, and standards.
EN50131-1 grade 2
Installation/Configuration Notes
Compatibility Information
Batteries
D126 12 V, 7 Ah Standby Battery
D1218 12 V, 18 Ah Standby Battery
D1240 12 V, 4 Ah Standby Battery
Keypads
DS7445i LED Keypad
DS7445V2 LED Keypad
DS7446KP LCD Keypad
DS7447E LCD Keypad
DS7447V2 LCD Keypad
Fire Detectors
D132A Smoke Detector Reversing Relay
DS250 Photoelectric Smoke Detector
DS250TH Photoelectric Smoke Detector with
heat-sensing thermistor
DS284 Photoelectric Smoke Detector
DS284TH Photoelectric Smoke Detector with
heat-sensing thermistor
DS284THS Photoelectric Smoke Detector with heat-
sensing thermistor and sounder
Wireless Prod-
ucts
RF280ETHS Wireless Photoelectric Smoke Detector
with heat-sensing thermistor and sounder
RF835E Wireless TriTech
®
Detector
RF940E Wireless PIR Detector
RF1100E RF Glass Break Detector
Batteries
D126 12 V, 7 Ah Standby Battery
RF3227E RF Receiver
RF3332E Two-button Keyfob
RF3334E Four-button Keyfob
RF3401E RF Transmitter
RF3405E RF Inertia Transmitter
RF3501E RF Panic Pendant
RF3503E RF Panic Button
Modules
DACM Door Access Control Module
DX2010 Eight-input Expander
DX2011 Eight-input Expander - D203 Metal Enclosure
DX2012 Eight-input Expander - AE20 Plastic Enclosure
DX3010 Octo-output Expander
DX3020 X-10 Control Module
DX4010 RS-232 Serial Interface Module
DX4010i RS-232 Serial Interface Module
DX4020 Network Interface Module
rvm4c Remote Video Module
Wiring Considerations
•
Up to 305 m (1,000 ft) allowed between panel/external
power supply and keypad or DACM when using 0.8 mm
wire.
•
Up to 610 m (2,000 ft) allowed between panel/external
power supply and keypad or DACM when using 1.2 mm
wire.
•
No more than two keypads/DACMs (0.8 mm) or three
keypads/DACMs (1.2 mm) are recommended on any
305 m (1,000 ft) run when powered from the panel.
Parts Included
Each standard system includes:
Quantity Component
1
DS7220V2 control board
1
Universal enclosure
1
Transformer (18 VAC, 50 VA)
1
Hardware/resistor pack
Technical Specifications
Data Bus
Data Bus:
12 VDC nominal
Enclosure
Material:
1.0 mm, cold-rolled steel
Dimensions:
36.8 cm x 31.8 cm x 7.6 cm
(14.5 in. x 12.5 in. x 3 in.)
Environmental Considerations
Relative Humidity:
5% to 85% at +30°C (+86°F) non-condens-
ing
Temperature (Operating):
0°C to +49°C (+32°F to +120°F)
Bosch Security Systems B.V.
www.boschsecurity.com
1