Executing calibration using the image controller – Konica Minolta bizhub PRESS C1070 User Manual
Page 86
5-28
5.2
Image Quality Adjustment
Executing calibration using the image controller
This section describes how to carry out calibration for daily maintenance using Fiery Command WorkStation and a
colorimeter (EFI Spectrometer ES-1000).
Tips
This section describes how to carry out calibration when using coated paper as an example.
A
Use a USB cable to connect EFI Spectrometer ES-1000 to your computer.
For information about EFI Spectrometer ES-1000 setting and adjustment, refer to the manual supplied
with this machine.
B
Start Fiery Command WorkStation.
For information about how to start this application, refer to page 3-16.
C
Click [Job Center] - [Calibrate] in
sequence.
Calibrator starts.
D
Select the printing preferences for
calibration.
-
Calibrate: Coated
-
Paper source: Paper tray with coated paper
loaded
-
Measurement method: EFI ES-1000
NOTICE
NOTICE
This section describes how to specify a printing
environment when using coated paper as an example.
Specify a printing environment according to the paper
and tray actually used.