5-11
bizhub PRO C1060L
bizhub PRESS C1070/C1070P/C1060
5
N
Press [Exit Print Mode].
O
Measure a misalignment between the
marks of [1] to [4] printed on the
[back] side of the output chart and the
marks on the [front] side.
-
The figure shows an example to measure [1].
The scale resolution is 0.5 mm.
-
In this figure, the black mark
indicates
the front side and the blue mark
indicates the back side.
-
Measure a misalignment between printing
positions in the horizontal direction (X axis)
and vertical direction (Y axis).
-
The measurement value can be entered in
units of up to 0.1 mm.
-
For example, as shown in the figure, if
at point [1] is misaligned 2.0 mm in the plus
side of the X direction and 1.5 mm in the minus side of the Y direction compared with the front side,
press [2] - [0] - [+/-] in the X direction to enter "-2.0" as the adjustment value, and press [1] - [5] in
the Y direction to enter "+1.5" as the adjustment value. Then, at point [1], the blue line on the back
side will be moved 2.0 mm in the minus side of the X direction and 1.5 mm in the plus side of the Y
direction.
-
Write down the measured values so that you do not forget them.
back
[1]
+
+
-
-
x
y