Konica Minolta bizhub PRESS C1070 User Manual
Page 63
5-5
bizhub PRO C1060L
bizhub PRESS C1070/C1070P/C1060
5
H
Press [a] to [d] of each point, and enter the adjustment value using the keypad, [,], or
[+] on the screen.
-
If the printing position is misaligned to the minus (-) side, enter a positive value (+). If the printing
position is misaligned to the plus (+) side, enter a negative value (-).
-
To reset a numeric value, press [Clear].
-
To switch the positive sign (+) and negative sign (-), press [+/-].
I
When entry processing is completed,
press [Adjustment Start].
The entered adjustment values are applied.
If [Back Side Magnification Adjustment] is set to
[OFF], the value of [d] (adjustment value of the
transverse magnification (Horizontal) on the back
side) is not applied.
J
Press Start on the control panel.
A test chart is printed out.