Diskette drive problems, General problems, Hard disk drive problems – Lenovo ThinkServer TD100x User Manual
Page 90: Diskette, Drive, Problems, General, Hard, Disk
![background image](/manuals/470798/90/background.png)
Diskette
drive
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Hardware
Maintenance
Manual
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
The
optional
diskette
drive
activity
LED
stays
lit,
or
the
server
bypasses
the
diskette
drive.
v
If
there
is
a
diskette
in
the
drive,
make
sure
that:
–
The
diskette
drive
cables
are
correctly
and
securely
connected.
–
The
diskette
drive
is
enabled
in
the
Configuration/Setup
Utility
program.
–
The
diskette
is
good
and
not
damaged.
(Try
another
diskette
if
you
have
one.)
–
The
diskette
is
inserted
correctly
in
the
drive.
–
The
diskette
contains
the
necessary
files
to
start
the
server.
–
Your
software
program
is
working
properly.
v
To
prevent
diskette
drive
read/write
errors,
make
sure
that
the
distance
between
monitors
and
diskette
drives
is
at
least
76
mm
(3
in.).
If
the
problem
remains,
replace
the
internal
diskette
drive
(see
the
Hardware
Maintenance
Manual).
General
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Hardware
Maintenance
Manual
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
A
cover
lock
is
broken,
an
LED
is
not
working,
or
a
similar
problem
has
occurred.
If
the
part
is
a
CRU,
replace
it.
If
the
part
is
a
FRU,
the
part
must
be
replaced
by
a
trained
service
technician.
Hard
disk
drive
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Hardware
Maintenance
Manual
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
Not
all
drives
are
recognized
by
the
hard
disk
drive
diagnostic
test
(the
Fixed
Disk
Test).
Remove
the
drive
that
is
indicated
by
the
diagnostic
tests;
then,
run
the
hard
disk
drive
diagnostic
test
again.
If
the
remaining
drives
are
recognized,
replace
the
drive
that
you
removed
with
a
new
one.
The
server
stops
responding
during
the
hard
disk
drive
diagnostic
test.
Remove
the
hard
disk
drive
that
was
being
tested
when
the
server
stopped
responding,
and
run
the
diagnostic
test
again.
If
the
hard
disk
drive
diagnostic
test
runs
successfully,
replace
the
drive
that
you
removed
with
a
new
one.
74
ThinkServer
TD100
and
TD100x
Types
4203,
4204,
4205,
4206,
6398,
6399,
6419,
and
6429:
Installation
Guide