Post error codes, Post, Error – Lenovo ThinkServer TD100x User Manual
Page 78: Codes

POST
error
codes
The
following
table
provides
an
abbreviated
list
of
the
error
codes
that
might
appear
during
POST.
See
the
Hardware
Maintenance
Manual,
which
is
available
on
the
Lenovo
Support
Web
site,
for
more
information
about
the
POST
error
codes.
To
check
for
updated
technical
information,
go
to
Table
5.
Abbreviated
list
of
POST
error
codes
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Hardware
Maintenance
Manual
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
062
Three
consecutive
boot
failures
using
the
default
configuration.
1.
Update
the
system
firmware
to
the
latest
level
(see
the
Hardware
Maintenance
Manual).
2.
(Trained
service
technician
only)
Replace
the
system
board.
101
Tick
timer
internal
interrupt
failure.
(Trained
service
technician
only)
Replace
the
system
board.
102
Internal
timer
channel
2
test
failure.
(Trained
service
technician
only)
Replace
the
system
board.
151
Real-time
clock
error.
1.
Reseat
the
battery.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
161
Real-time
clock
battery
failure.
1.
Reseat
the
battery.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
62
ThinkServer
TD100
and
TD100x
Types
4203,
4204,
4205,
4206,
6398,
6399,
6419,
and
6429:
Installation
Guide