Table 3. indirectly addressed register overview, Cs4205 – Cirrus Logic CS4205 User Manual
Page 26
CS4205
26
DS489PP4
Reg Register Name
D15 D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0 Default
00h
PCM Input Volume
Mute
0
GL5
GL4
GL3
GL2
GL1
GL0
0
0
GR5 GR4 GR3 GR2 GR1 GR0
8000h
01h
ADC Input Volume
Mute
0
GL5
GL4
GL3
GL2
GL1
GL0
0
0
GR5 GR4 GR3 GR2 GR1 GR0
8000h
02h
SDI1 Volume
Mute
0
GL5
GL4
GL3
GL2
GL1
GL0
0
0
GR5 GR4 GR3 GR2 GR1 GR0
8000h
03h
SDI2 Volume
Mute
0
GL5
GL4
GL3
GL2
GL1
GL0
0
0
GR5 GR4 GR3 GR2 GR1 GR0
8000h
04h
SDI3 Volume
Mute
0
GL5
GL4
GL3
GL2
GL1
GL0
0
0
GR5 GR4 GR3 GR2 GR1 GR0
8000h
05h
ZV Volume
Mute
0
GL5
GL4
GL3
GL2
GL1
GL0
0
0
GR5 GR4 GR3 GR2 GR1 GR0
8000h
06h
SDOUT Volume
Mute
0
GL5
GL4
GL3
GL2
GL1
GL0
0
0
GR5 GR4 GR3 GR2 GR1 GR0
8000h
07h
SDO2 Volume
Mute
0
GL5
GL4
GL3
GL2
GL1
GL0
0
0
GR5 GR4 GR3 GR2 GR1 GR0
8000h
08h
SP Engine Control
Res
SDI1M SRZC1 SRZC0 LPFS1 LPFS0 HPFS1 HPFS0 GL3
GL2
GL1
GL0
GR3 GR2 GR1 GR0
1800h
09h
IEC Config
EROF ELOF
MROF
MLOF
0
AMOR AROR
ALOR
0
0
0
0
0
0
0
0
0000h
0Ah
IEC Wakeup
EROF ELOF
MROF
MLOF
0
AMOR AROR
ALOR
0
0
0
0
0
0
0
0
0000h
0Bh
IEC Status
EROF ELOF
MROF
MLOF
0
AMOR AROR
ALOR
0
0
0
0
0
0
0
0
0000h
0Ch
BDI Config
E15
E14
E13
E12
E11
E10
E9
E8
E7
E6
E5
E4
E3
E2
E1
E0
0000h
0Dh
BDI Wakeup
E15
E14
E13
E12
E11
E10
E9
E8
E7
E6
E5
E4
E3
E2
E1
E0
0000h
0Eh
ZV Port Ctrl/Stat 1
ZVEN LOCK
0
Ph24
Ph23
Ph22
Ph21
Ph20
Ph19 Ph18 Ph17 Ph16 Ph15 Ph14 Ph13 Ph12
0000h
0Fh
ZV Port Ctrl/Stat 2
Reserved
Ph11
Ph10
Ph9
Ph8
Ph7
Ph6
Ph5
Ph4
Ph3
Ph2
Ph1
Ph0
0000h
Table 3. Indirectly Addressed Register Overview