beautypg.com

Kramer Electronics TP-107AV User Manual

Page 23

background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Configuring a TP-107V / TP-107AV System

20

5.5 Connecting via the RS-485

You can interconnect the

TP-107AV units together with an RC-108/RC-116

controller via RS-485 communication (using the C-STP+KNET-6 cables), as

illustrated in Figure 17.

K-NET (RS-485) PINOUT

GND

Green

Black

Red

White

+12V

+

-

B

A

Figure 17: Wiring the RS-485 Connector

5.6 Setting the Dipswitches of the TP-107AV

Figure 18 and Table 13 define the factory default dipswitches:

OFF

ON

1 2 3 4 5 6 7 8

Figure 18: Dipswitch Settings

Table 13: Dipswitch Setting Features

DIPS

Description

1, 2, 3, 4

Set the machine number for each TP-107AV/TP-107V in the chain (see Table 14)

5, 6, 7

Not used

8

Set to ON for a standalone unit
Set to OFF when in slave mode