Kramer Electronics TP-107AV User Manual
Page 12
Your Line Transmitters and Presentation Controllers
9
Table 3: TP-107V / TP-107AV (Top Panel) Features
#
Feature
Function
1
CONTROL Dipswitches
DIPs 1, 2, 3 and 4 determine the machine number; DIP 8 sets to
standalone or slave mode; DIPs 5, 6 and 7 are reserved
2
LINE IN 1 RJ-45 Connector
Connects to
1
the LINE OUT RJ-45 connector on the previous line
transmitter
3
LINE OUT 2 RJ-45 Connector Connects to
1
the LINE IN RJ-45 connector on the receiver
2
or the
next line transmitter
4
RS-485 and 12V DC PINs
PIN GND is for the Ground connection; PIN B (-) and PIN A (+) are
for RS-485
3
or RS-232
4
, and PIN +12V is for powering the unit
5
5
XGA IN 15-pin HD Connector Connects to the XGA source
6
ONLINE Button
Press to access priority
7
ON LED
Lights when receiving power
8
Audio IN 3.5mm Mini Jack
Connects to the audio source (applies only to the TP-107AV)
Figure 4 and Table 4 define the underside of the
TP-107V / TP-107AV:
Figure 4: TP-107V / TP-107AV Underside Panel reference
1 Using CAT 5 cable with RJ-45 connectors at both ends (the PINOUT is defined in Table 11 and Figure 15)
2 For example, the Kramer TP-120 or TP-122. You can download this user manual at: http://www.kramerelectronics.com
3 Connects to the RS-232 9-pin D-sub port on a Kramer (or other) device or PC (when both RS-232 underside switches are set
to the left)
4 When both underside RS-232 switches are set to the right
5 The 12V DC power supply (provided) is used to power the system (see Table 1)