Kramer protocol – Kramer Electronics VP-88K User Manual
Page 52

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Kramer Protocol
48
Preset commands
Command
Syntax
Response
Parameters Description:
PRESET = Preset number.
OUT = Output in preset to show for, '*' for all.
Examples
Store current Audio & Video
connections to preset 5
#PRST-STR 5
CR
~PRST-STR 5 OK
CRLF
Recall Audio & Video connections
from preset 3
#PRCL 3
CR
~PRST-RCL 3 OK
CRLF
Show source of video output 2 from
preset 3
#PRST-VID? 3,2
CR
~PRST-VID 3: 4>2
CRLF
Operation commands
Command
Syntax
Response
Lock front panel
LOCK-FP LOCK-MODE
Short form: LCK LOCK-MODE
LOCK-FP LOCK-MODE RESULT
Get front panel locking state
LOCK-FP?
LOCK-FP LOCK-MODE
Parameters Description:
LOCK-MODE = Front panel locking state:
"0" or "off" to unlock front panel buttons.
"1" or "on" to lock front panel buttons.
Restart device
RESET
RESET OK
Switch to protocol 2000*
P2000
P2000 OK
* Protocol 2000 has command to switch back to ASCII protocol (like protocol 3000)
Audio parameters commands
Command
Syntax
Response
Set audio level in specific
amplifier stage.
AUD-LVL STAGE, CHANNEL, VOLUME
Short form: ADL STAGE, CHANNEL, VOLUME
AUD-LVL STAGE, CHANNEL,
VOLUME RESULT
Read audio volume level
AUD-LVL? STAGE, CHANNEL
Short form: ADL? STAGE
AUD-LVL STAGE, CHANNEL,
VOLUME
Mute Audio
MUTE MUTE MODE
MUTE MUTE MODE RESULT