Table 2, Defining the rgbhv/balanced audio matrix switcher – Kramer Electronics VP-88K User Manual
Page 11

Defining the RGBHV/Balanced Audio Matrix Switcher
7
7
Table 2: RGBHV/Balanced Audio Matrix Switcher Rear Panel Features
#
Feature
Function
1
INPUT BNC connectors
Connect to the RGBHV video sources (or composite video, Y/C, YUV,
and even SD – SDI signals on different inputs)
2
OUTPUT BNC connectors
Connect to the RGBHV video acceptors
3
REMOTE IR 3.5mm mini
connector
(Optional, requires a special order cable) Connect to an external IR
receiver unit for controlling the machine via an IR remote controller
(instead of using the front panel IR receiver)
4
EXT. SYNC BNC connector
Connects to the external sync source
5
EXT./IN 1 Button
When pushed in selects an external sync from the external source;
when released selects the internal sync (inputted via the video input #1
connectors) (see
Section 7.9
6
RS-232 9-pin D-sub port
Connects to the PC or the remote controller
7
RS-485 Term switch
Terminates the RS-485 bus (see
Section 6.5
8
Machine # DIP-switches
DIP-switches for setup of the unit: 5, 6, 7, and 8 set the machine
number; 1 sets the RS-485 bus termination (see
Section 6.5
9
RS-485 Port
Pin G is for the Ground connection
10
; pins B (-) and A (+) are for RS-485;
12V is connected to the 12V power
Mains power switch
Illuminated switch for turning the unit ON or OFF
11
Mains fuse holder
Contains the mains fuse
12
Mains power socket
Socket for a mains power cable
13
FACTORY RESET Button
Press and hold while powering up the unit to reset the audio,
switching and Ethernet settings to their factory default values:
IP number
192.168.1.39
Mask
255.255.255.0
Gateway
192.168.1.1
Audio gain for all inputs and
outputs
0dB
All switching configuration
Erased
Display
1, 2, 3, 4, 5, 6, 7, 8
Audio mode
AFV
14
ETHERNET RJ-45 Connector Connects to the PC or other serial controller through the computer
network
15
PROGRAM Button
Push in to enter Program mode to upgrade to the latest Kramer firmware
via RS-232; Release to revert to Normal mode (the factory default)
16
AUDIO OUTPUTS removable
terminal blocks
Connect to the balanced stereo audio acceptors
17
AUDIO INPUTS removable
terminal blocks
Connect to the balanced stereo audio sources
1 Can be used instead of the front panel (built-in) IR receiver to remotely control the machine (see
2 The ground connection is sometimes connected to the shield of the RS-485 cable. In most applications, the ground is not connected