beautypg.com

Table 2, Defining the rgbhv/balanced audio matrix switcher – Kramer Electronics VP-88K User Manual

Page 11

background image

Defining the RGBHV/Balanced Audio Matrix Switcher

7

7

Table 2: RGBHV/Balanced Audio Matrix Switcher Rear Panel Features

#

Feature

Function

1

INPUT BNC connectors

Connect to the RGBHV video sources (or composite video, Y/C, YUV,

and even SD – SDI signals on different inputs)

2

OUTPUT BNC connectors

Connect to the RGBHV video acceptors

3

REMOTE IR 3.5mm mini

connector

(Optional, requires a special order cable) Connect to an external IR

receiver unit for controlling the machine via an IR remote controller

(instead of using the front panel IR receiver)

1

4

EXT. SYNC BNC connector

Connects to the external sync source

5

EXT./IN 1 Button

When pushed in selects an external sync from the external source;

when released selects the internal sync (inputted via the video input #1

connectors) (see

Section 7.9

6

)

RS-232 9-pin D-sub port

Connects to the PC or the remote controller

7

RS-485 Term switch

Terminates the RS-485 bus (see

Section 6.5

8

)

Machine # DIP-switches

DIP-switches for setup of the unit: 5, 6, 7, and 8 set the machine

number; 1 sets the RS-485 bus termination (see

Section 6.5

9

)

RS-485 Port

Pin G is for the Ground connection

2

10

; pins B (-) and A (+) are for RS-485;

12V is connected to the 12V power

Mains power switch

Illuminated switch for turning the unit ON or OFF

11

Mains fuse holder

Contains the mains fuse

12

Mains power socket

Socket for a mains power cable

13

FACTORY RESET Button

Press and hold while powering up the unit to reset the audio,

switching and Ethernet settings to their factory default values:

IP number

192.168.1.39

Mask

255.255.255.0

Gateway

192.168.1.1

Audio gain for all inputs and

outputs

0dB

All switching configuration

Erased

Display

1, 2, 3, 4, 5, 6, 7, 8

Audio mode

AFV

14

ETHERNET RJ-45 Connector Connects to the PC or other serial controller through the computer

network

15

PROGRAM Button

Push in to enter Program mode to upgrade to the latest Kramer firmware

via RS-232; Release to revert to Normal mode (the factory default)

16

AUDIO OUTPUTS removable

terminal blocks

Connect to the balanced stereo audio acceptors

17

AUDIO INPUTS removable

terminal blocks

Connect to the balanced stereo audio sources




1 Can be used instead of the front panel (built-in) IR receiver to remotely control the machine (see

Section 4.1

)

2 The ground connection is sometimes connected to the shield of the RS-485 cable. In most applications, the ground is not connected