Connecting the RGBHV/Balanced Audio Matrix Switcher
17
17
Table 3: DIP-switch Settings
#
DIP-switch Number
Function
1 1
RS-485 Termination
2 2, 3, 4
Not used
3 5, 6, 7, 8
Machine number (see
DIP-switch 1 determines the RS-485 bus termination for the VP-88K. Moving the
switch up turns the termination off (default), moving the switch down turns the
termination on.
DIP-switches 2, 3, and 4 are not used.
DIP-switches 5, 6, 7, and 8 determine the machine number of the VP-88K. When
several VP-88K units are connected, the machine number determines the unique
identity of the VP-88K in the sequence (see
•
When using a stand-alone VP-88K unit, set the machine number to 1 (factory
default)
•
When connecting more than one VP-88K, set the first machine (connected via
RS-232) to be machine number 1. The other VP-88K units must each be set to
a unique machine number between 2 and 16.
Table 4: Machine Number DIP-switch Settings
Machine Number
DIP-switch
Machine Number
DIP-switch
5
6
7
8
5
6
7
8
1
(Master, default)
OFF OFF OFF OFF
9 (Slave)
ON OFF OFF OFF
2 (Slave)
OFF OFF OFF ON
10 (Slave)
ON OFF OFF ON
3 (Slave)
OFF OFF ON OFF
11 (Slave)
ON OFF ON OFF
4 (Slave)
OFF OFF ON ON
12 (Slave)
ON OFF ON ON
5 (Slave)
OFF ON OFF OFF
13 (Slave)
ON ON OFF OFF
6 (Slave)
OFF ON OFF ON
14 (Slave)
ON ON OFF ON
7 (Slave)
OFF ON ON OFF
15 (Slave)
ON ON ON OFF
8 (Slave)
OFF ON ON ON
16 (Slave)
ON ON ON ON