beautypg.com

Table 3: dip-switch settings, Table 4: machine number dip-switch settings – Kramer Electronics VP-88K User Manual

Page 21

background image

Connecting the RGBHV/Balanced Audio Matrix Switcher

17

17

Table 3: DIP-switch Settings

#

DIP-switch Number

Function

1 1

RS-485 Termination

2 2, 3, 4

Not used

3 5, 6, 7, 8

Machine number (see

Table 4

)

DIP-switch 1 determines the RS-485 bus termination for the VP-88K. Moving the

switch up turns the termination off (default), moving the switch down turns the

termination on.
DIP-switches 2, 3, and 4 are not used.
DIP-switches 5, 6, 7, and 8 determine the machine number of the VP-88K. When

several VP-88K units are connected, the machine number determines the unique

identity of the VP-88K in the sequence (see

Table 4

).

When using a stand-alone VP-88K unit, set the machine number to 1 (factory

default)

When connecting more than one VP-88K, set the first machine (connected via

RS-232) to be machine number 1. The other VP-88K units must each be set to

a unique machine number between 2 and 16.

Table 4: Machine Number DIP-switch Settings

Machine Number

DIP-switch

Machine Number

DIP-switch

5

6

7

8

5

6

7

8

1

(Master, default)

OFF OFF OFF OFF

9 (Slave)

ON OFF OFF OFF

2 (Slave)

OFF OFF OFF ON

10 (Slave)

ON OFF OFF ON

3 (Slave)

OFF OFF ON OFF

11 (Slave)

ON OFF ON OFF

4 (Slave)

OFF OFF ON ON

12 (Slave)

ON OFF ON ON

5 (Slave)

OFF ON OFF OFF

13 (Slave)

ON ON OFF OFF

6 (Slave)

OFF ON OFF ON

14 (Slave)

ON ON OFF ON

7 (Slave)

OFF ON ON OFF

15 (Slave)

ON ON ON OFF

8 (Slave)

OFF ON ON ON

16 (Slave)

ON ON ON ON