Table 9-3. mx2800 alarm events -12, Table 9-3, Listed in – ADTRAN MX2800 M13 User Manual
Page 136: M event
9-12
6120
029
0L1-1
G
Section 9, Tran
sacti
on Lan
gua
ge 1 (TL1
)
M
X2
800
M13
Multip
lexer Syste
m
Manu
al
Table 9-3. MX2800 Alarm Events
AID
Notification
Code
Condition
Type
Service
Affecting
Location
Description
Recommended Action
REPT
ALM
T1
101-128
MN
ACTLPBK
SA
NEND
DS1 In-test
No action. (This alarm is normal during DS1 loopback tests).
101-128
MJ
LOS
SA
NEND
Loss Of Signal
Check DS1 facility entering MX2800 for valid signal.
REPT
ALM
T2
201-207
MJ
OOF
SA
NEND
DS2 Out Of Frame
Check for DS3 alarms. If none, check settings at far-end M13
multiplexer.
201-207
MJ
RAI
SA
FEND
DS2 Remote Alarm Indication
Check status Of DS2 at far-end M13 multiplexer.
REPT
ALM
T3
301
MN
TSA
SA
NEND
DS3 in-test
No action (This alarm is normal during DS3 loopback tests.)
301
MN
EXT-DS3
SA
FEND
FEND DS3 Equipment failure
SA
Examine far-end M13 multiplexer to determine the reason it has
signaled this condition.
301
MN
LOS
SA
FEND
FEND DS3 Loss of Signal
Check DS3 facility entering the far-end M13 multiplexer.
301
MN
OOF
SA
FEND
FEND DS3 Out of Frame
Check DS3 facility entering the far-end M13 multiplexer
(including checking the provisioned DS3 framing type).
301
MN
AIS
SA
FEND
FEND DS3 Alarm Indication
Signal
Check status of DS3 at far-end M13 multiplexer.
301
MN
ISD
SA
FEND
FEND DS3 Idle
Check for DS3 idle signal at far-end M13 multiplexer.
301
MN
EXT-DS3
NSA
FEND
FEND DS3 Equipment Failure
NSA
Examine far-end M13 multiplexer to determine the reason it has
signaled this condition.
301
MN
EXT
NSA
FEND
FEND Common Equipment
Failure
Examine far-end M13 multiplexer to determine the reason it has
signaled this condition.
301
MN
LOS-M
SA
FEND
FEND Multiple DS1 Loss of
Signal
Check for loss of signal at DS1 ports on far-end M13 multi-
plexer.
301
MN
EXT-DS1
SA
FEND
FEND DS1 Equipment Failure
SA
Examine far-end M13 multiplexer to determine the reason it has
signaled this condition.
301
MN
LOS-S
SA
FEND
FEND Single DS1 Loss of
Signal
Check for loss of signal at DS1 ports on far-end M13 multi-
plexer.