Bell & Gossett P5002169C Series VSCS User Manual
Page 21

19
1. Wipe dirt from the grease fittings before greasing.
2. Fill both of the grease cavities through the fittings
with the recommended grease. Stop when grease
leaks out at shaft.
3. If needed, stop pump and wipe off excess grease.
Specifications – Grease Types
Polyurea based greases:
1. ExxonMobile Polyrex™ EM
2. Chevron SRI NLGI 2
3. Shell Gadus® S5 T100 2
Polyurea based grease are the only recommended
greases. Do not use other grease.
See the motor service instructions and name-
plate for motor regreasing information. Pumps
are to be regreased during pump reassembly
using the grease types listed below or approved
equal. After bearings are assembled on shaft
wait until cool to hand pack bearings.
NOTICE:
Make sure the grease container, the greasing device,
and the fittings are clean. Failure to do so can result
in impurities entering the bearing housing when you
regrease the bearings.