6. Use the 1 1/8” wrench to slowly
loosen
the Cap side Hoses
(CH1), (CH2). Check for fluid
flow. Bleed any pressure.
Disconnect
the Cap side Hoses
(CH1), (CH2).
7. Use the 1” wrench to slowly
loosen
the Rod side Hose (RH).
Check
for fluid flow. Bleed any
pressure. Disconnect the Rod
side
Hose (RH).
8. Pull out the Torque Cylinder
Safety Clip (SC).
9. Use the Torque Cylinder Safety
Clip
(SC) to pull out the Torque
Cylinder Rod Pin (P).
10. Disconnect the Low Torque
Warning System Hydraulic Hoses
(HH & HH1).
11. Use the 1 1/8” wrench and 5/8”
Allen wrench to remove the Top
Torque Cylinder Mount Bolts
(TBH), (TBA).
12. Use the 1 1/8” wrench to remove
all Four Bottom Torque
Cylinder Mount Bolts (BB).
13. Slide out the Torque Cylinder (C).
14. Remove the Bottom Trunion
Mount
Plate (BMP) and the Top
Trunion Mount Plate (TMP).