Setting make up torque – Hawk Industries Hawkjaw Jr. Manual 65K-ALS Serial Numbers 4 to 9 User Manual
Page 22

Setting Make Up Torque
Operation
K
S
T
TN
Shown set for 30,000 ft. lbs.
RNA
RN
G
22
Operation
1. Follow the steps on pages 14-21.
2. Use the Red needle adjust (RNA)
to rotate the Torque gauge red
needle (RN) to the desired
torque.
3. Rotate the Torque Set knob (K)
counter- clockwise as far as the
Torque Set knob (K) will turn.
4. Press and hold Spin (S) until the
stand rotates down to the
shoulder.
5. Release Spin (S).
6. Push in the wrench Grip (G).
7. Press and hold Torque (T). While
holding down Torque (T), rotate
the Torque Set knob (K) clock-
wise.
8. When the Torque gauge needle
(TN) reaches the desired torque,
stop rotating the Torque Set knob
(K).
9. Release Torque (T). Immediately
release the wrench Grip (G).
10. The Hawkjaw torque is now set
and can now be removed from the
pipe.