beautypg.com

Beijer Electronics MT 223 EN User Manual

Page 34

background image

© Elektronik-Systeme LAUER GmbH & Co. KG • 2007

34

7.15. Digital OUT

Target application:

The outputs are used to give around e.g. externally acoustic or visual (alarm) signals.

Function:

The contacts „digitally Out 1“ and „digitally Out 2“ are activated by the controller. They can be linked with the inputs

„digitally in“ or in addition, over the serial or LAN interface to be set. „digitally Out 1“ is directly coupled with the Buzzer

on the front plate.

Plug:

4 pol Phoenix plug with “screw safety lock” RM3,81 for lines to 1,5mm²

Connection:

Pin

Function

Description

1

Digital Out 1

Normally open contact 1

2

Digital Out 1

Normally open contact 1

3

Digital Out 2

Normally open contact 2

4

Digital Out 2

Normally open contact 2

Connection data:

Relay contact 24V DC/1A or 230V AC/0,1A

7.16. Remote Power

Target application:

This switching contact is meant for remote control (off and on) to the picture signal giving PC‘s. Lauer Nautic PC‘s

have an appropriate input. So that the OFF/ON goes from monitor and PC synchronously, the PC should switch itself

on automatically when putting on supply voltage.

Function:

The contact is closed if the power key approx. 1s is pressed, and opens again if the power key is released.

Plug:

2 pol Phoenix plug with “screw safety lock” RM3,81 for lines to 1,5mm²

Connection:

Pin

Function

Description

1

Remote-Power

Normally open contact

2

Remote-Power

Normally open contact

Connection data: