Appendix E: Codes and error messages
228
0B60:
DIMM bank 1 has been
disabled
Memory error, memory bank
1 failed
0B61:
DIMM bank 2 has been
disabled
Memory error, memory bank
2 failed
0B62:
DIMM bank 3 has been
disabled
Memory error, memory bank
3 failed
0B6F:
DIMM bank with error is
enabled
An error detected in all the
memory
0B70:
The error occurred during
temperature sensor reading
Error while detecting a
temperature failure.
0B71:
System temperature out of
the range
Temperature error detected.
0B74:
The error occurred during
voltage sensor reading
Error while detecting voltage
0B75:
System voltage out of the
range
System voltage error
0B7C:
The error occurred during
redundant power module
confirmation
The error occurred while
retrieving the power
information.
0B80:
BMC Memory Test Failed
BMC device (chip) failed
0B81:
BMC Firmware Code Area
CRC check failed
BMC device (chip) failed
0B82:
BMC core Hardware failure
BMC device (chip) failed
0B83:
BMC IBF or OBF check failed
Access to BMC address failed
0B90:
BMC Platform Information
Area corrupted.
BMC device (chip) failed
0B91:
BMC update firmware
corrupted.
BMC device (chip) failed
Code
Error Message
Failure Description
AA G900 ug - EN.book Page 228 Wednesday, September 25, 2002 5:23 PM