beautypg.com

Ues with the, Thresholds, Screen – Avaya P130 SMON User Manual

Page 48: Set thresholds

background image

Chapter 7

41

Avaya P130 SMON User Guide

Set

Thresholds

The Set Thresholds screen enables you to configure the behavior of the

Alarms and Events tool when SMON is started, and to configure

thresholds for the Alarm.

There are two thresholds, a Rising Threshold and a Falling Threshold. If

the rate of the selected counter rises above the selected Rising Threshold,

an Event is generated. If the rate of the selected counter falls below the

selected Falling Threshold, an Event is generated. For more information

about Thresholds, refer to

“Alarms and Events Overview” on page 6

.

Figure 7-6. Alarm Wizard - Set Thresholds

To configure the behavior of the Alarms and Events tool when SMON is

started, select a radio button in the

Alarm Startup

field. The options are:

• Rising - The first Event that can be generated must be a Rising

Event. If the rate falls below the Falling Threshold before it rises

above the Rising Threshold, a Falling Event is not generated.

• Falling - The first Event that can be generated must be a Falling

Event. If the rate rises above the Rising Threshold before it falls

below the Falling Threshold, a Rising Event is not generated.

• Rising and Falling - The first Event generated can be a Rising or a

Falling Event.

To configure the thresholds, enter values in the

Rising

and

Falling

fields. The

threshold levels are in packets or octets per second.

When you finish configuring the startup behavior and thresholds, click

Next

. The Alarm Wizard continues with the

Descriptions