Avaya P130 SMON User Guide

34

Alarms and Events

Method

The method used for monitoring the variable. Possible

options are:

• Rate @ Interval - The Alarm uses the counter’s rate

in the last interval.

• Total - The Alarm uses the absolute number of the

counter from the time the device was last reset.

* Note: The Alarms and Events tool can only

configure Alarms using the

Rate @ Interval method. To configure

Alarms based on the absolute number of

packets, use the CLI (Command Line

Interface) or a third-party application.

Startup Alarm

The type of Event that can be generated as the first Event

for the Alarm. Possible types are:

• Rising - The first Event that can be generated must

be a Rising Event. If the rate falls below the Falling

Threshold before it rises above the Rising Threshold,

a Falling Event is not generated.

• Falling - The first Event that can be generated must

be a Falling Event. If the rate rises above the Rising

Threshold before it falls below the Falling Threshold,

a Rising Event is not generated.

• Rising and Falling - The first Event generated can

be a Rising or a Falling Event.

Rising Threshold The upper threshold for the counter.

Falling

Threshold

The lower threshold for the counter.

Owner

The owner of the Alarm. This is usually the person who

created the Alarm.

Table 7-1. Alarms Table Fields (Continued)

Field

Description