beautypg.com

Troubleshooting – Karcher BD 100-250 R I Bp User Manual

Page 25

background image

-

10

ƽ

Danger

Risk of injury if the machine is left running
in an unattended state. Before carrying out
any tasks on the machine, set the main key
to "0" and remove it. Press emergency-stop
button. Remove the battery plug.

Drain and dispose of the dirt water and
the residual fresh water.

In case of faults that cannot be remedied
using the table below please contact the
customer service.

The operator may only replace the follow-
ing vehicle flat fuses having the following
values:

7.5A (F1) – Control and emergency
power supply.

30A (F3) – Lift/accessories module sup-
ply.

80A (F6) – Lift/Clean module 2 (sweep-
er).

Note
Defective pole fuses should only be re-
placed by the service center. If these fuses
are defective, then customer service center
has to check the usage conditions and the
entire control system.
The control unit is located below the oper-
ating panel. To access the fuses the cover
on the left side of the foot compartment
must be removed in advance.

Turn out the fastening screws at the up-
per end of the cover.

Remove cover.

Replace fuse.

Replace cover.

Note
The population of fuses is displayed on the
inner side of the cover.

The display shows the existing faults at in-
tervals of 4 seconds (example:

Fault scrubbing
funktion H1/022

If the faults continue to be displayed on the
console even after 4 seconds, then pro-
ceed as follows:

Bring the key switch to "0" (switch off
the machine).

Wait till the text on the display has dis-
appeared.

Bring the key switch back to "1" (switch
on the machine). Carry out the trouble-
shooting measures in the given se-
quence only if the fault occurs again. At
such times, always bring the main
switch to the "0" position and ensure
that the emergency-stop button is de-
pressed.

If the fault cannot be repaired, call cus-
tomer service and mention the fault
code(s) (H1/022 in the example).

Troubleshooting

Replace fuses

Fault indication

25

EN