1 Plug for seat contact switch
Remove screw of seat stopper.
Pull out the plug of the seat contact
switch and push it back through the
opening.
Unlock the driver seat and pull it up-
ward.
Hang out the support for the seat brack-
et and tilt the seat bracket towards the
front.
Lift battery cover.
Insert battery. Battery connections in
front direction.
ṇ
Warning
Risk of damage due to inadvertent transpo-
sition of the battery terminals.
Pay attention to correct poles.
Connect the connection cable to the
free battery poles (+) and (-). Lay the
cables in such a way that they do not
get clamped by the seat.
Replace battery cover.
Insert battery plug.
Hang in the support for the seat brack-
et.
Insert the seat.
Reconnect the plug of the seat contact
switch.
Install screw of seat stopper.
Swivel the seat downward.
Caution
Risk of damage due to deep discharge of
batteries.
Charge the batteries before commissioning
the machine.
Note
The device is equipped with a safety mech-
anism to prevent total discharge, i.e. when
the permissible minimum capacity is
reached, then the machine can only be
driven and existing lamps can be switched
on. In such a case, the battery monitoring
symbol on the control console glows red.
Drive the machine directly to the charg-
ing station; avoid any steep gradients in
the process.
Note
While using other batteries (for e.g. batter-
ies from other manufacturers) the total dis-
charge protection level must be reset by
the Kärcher aftersales service according to
the respective battery.
ƽ
Danger
Risk of electric shock. Observe supply net-
work and fuse protection - see "Charger".
Only use the charger in dry rooms with suf-
ficient ventilation!
Note
Average charging time is approx. 10 - 12
hours.
The recommended chargers (matching the
batteries used) are regulated electronically
and will automatically switch off the charg-
ing process.
ƽ
Danger
Danger of explosion. Wet batteries can
only be charged with the seat tilted up.
Tilt the seat upward.
Remove battery plug and join it to the
charging cable.
Connect the charger to the mains and
turn it on.
Switch off the charger and remove the
plug from the socket.
Pull the battery cable from the charger
cable and connect it to the machine.
Add distilled water one hour before the
charging process comes to an end; fol-
low the correct acid level. There are
corresponding indicators on the battery.
At the end of the charging process, all
cells must gas.
ƽ
Danger
Danger of causticization!
–
Adding water to the battery in its dis-
charged state can cause the acid to
leak.
–
Use safety glasses while handling bat-
tery acid and follow the safety instruc-
tions to avoid personal injury or damage
to clothes.
–
Should the acid spray on to the skin or
clothes, rinse immediately with lots of
water.
Caution
Risk of damage!
–
Use only distilled or desalinated water
(EN 50272-T3) for filling the battery.
–
Do not add any substances (so-called
performance improving agents), else
warranty claims will not be entertained.
Batteries and chargers are available in spe-
cialised stores.
If you use wet batteries in the BAT model,
then follow the following instructions:
–
It is necessary to conform to the maxi-
mum battery dimensions.
–
While charging wet (maintenance-free)
batteries, it is necessary to tilt the seat
upward.
–
While charging wet batteries, follow the
specifications of the battery manufac-
turer.
Charge the batteries
After charging
Low maintenance batteries (wet batter-
ies)
Recommended batteries, chargers
Order No.
Battery set
6.654-136
Charger
6.654-044
Maximum battery dimensions
Length
Width
Height
842 mm
627 mm
537 mm