Introduction, Parts list, Product specifications – HID VertX EVO V2000 Installation Guide User Manual
Page 3: Cable specifications
VertX EVO V2000 Installation Guide, 72000-902, rev A.2
April 2012
Page 3 of 18
© 2003 - 2012 HID Global Corporation. All rights reserved.
Introduction
HID’s VertX EVO open platform is flexible and scalable to permit economic and high performance access control
solutions for a wide range of applications. The VertX EVO V2000 interconnects through different sub-networks and
protocols to a standard TCP/IP network with the capability of a variety of applications.
For example, the VertX EVO V2000 Reader Interface / Access Controller is a cost-effective method for two-way
communication using Ethernet between a computer and a V2000.
Parts List
Description
Quantity
VertX EVO™ V2000 (Reader Interface / Access Controller)
Note: Each VertX EVO V2000 has a plastic base and is covered with a plastic lid.
1 V2000
- Lithium Battery
1
- Mounting screws
4
- 2.2K EOL resistors
8 ea V2000
- Quick Installation Guide
1
- Installation Wiring Diagram Example
1
Product Specifications
Description
Specification
Power Supply Input
12-24VDC
Maximum Current at 12-24VDC per Unit
1 Amp
Average Operating Current at 12VDC
625mA (with two R40 iCLASS Readers)
Reader Power Output
12VDC, 250mA each
Relay Outputs
30VDC, 2Amp, resistive
Operating Temperature Range
32°-120°F (0°- 49°C)
Humidity
5% to 85% non-condensing
Cable Specifications
Cable Type
Length
Specification
Input Circuits *
500 feet (150 m)
2-conductor, shielded, using ALPHA 1292C (22AWG) or Alpha 2421C
(18AWG), or equivalent.
Output Circuits *
500 feet (150 m)
2-conductor, using ALPHA 1172C (22AWG) or Alpha 1897C (18AWG),
or equivalent.
Wiegand
500 feet (150 m) to reader
ALPHA 1299C, 22AWG, 9-conductor, stranded, overall shield.
Fewer conductors needed if all control lines are not used.
Ethernet
328 feet (100 m)
Cat5, Cat5E, and Cat6
Power Supply
12-24 VDC IN
----
Refer to your Power Supply Installation Guide. Not Provided.