3 wiring, 1 standard wire connections, 2 buffered direct wire connections – option d – HID ProxPro Installation Guide User Manual
Page 5: 3 direct wire connections – option s, Wiring, Standard wire connections, Buffered direct wire connections – option d, Direct wire connections – option s
![background image](/manuals/433080/5/background.png)
ProxPro
®
Installation Guide
Part No. 5355-900, Rev N.1
3 Wiring
3.1 Standard Wire Connections
TB1
1
2
3
4
5
6
7
8
9
10
11
+DC Ground
Data0/
Data
Data1/
Clock
Shield
Ground
Green
LED
Red
LED
Beeper Hold/
Card
Present
Tamper
Common
Tamper
Select
Red Black
Green
White
Violet
Orange
Brown
Yellow
Blue --
--
3.2 Buffered Direct Wire Connections – Option D
10
11
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
Tamper
Common
Tamper
Select
+DC
Ground
Row 1
Row 2
Row 3
Row 4
Column
1
Column
2
Column
3
Select
Low
Red /
Black
Red /
Green
White /
Red
White /
Black
Gray Violet Red
/
Yellow
Pink Tan White
/
Blue
White /
Green
White /
Yellow
3.3
Direct Wire Connections – Option S
TB2
1
2
3
4
5
6
7
Row 1
Row 2
Row 3
Row 4
Column 3
Column 2
Column 1
Red Black
Green
White
Drain Orange
Brown
Notes:
1. When
using
5 conductor cable, the power supply and Host must have a common ground (voltage
reference).
2. 6 conductor cable is required when controlling the red and green LED. (Alpha 1296 C or
equivalent)
3. 7 conductor cable is required when both green and red LED’s are controlled by the Host and the
power supply and Host "ground" are separate. (Alpha 1297 C or equivalent)
4. A 22 AWG twisted pair, shielded, stranded cable is often required for the tamper switch. Follow the
recommendations of the manufacturer of the Host system. If the tamper input is a supervised input
the "end of line" resistors may be mounted in the enclosure. Use extreme care and shield any bare
wire from the printed circuit assembly and its components.
5. The inner diameter of the cable fitting will accommodate a cable with an outer diameter of .300
inches (nominally).
6. Connect cable shield by connecting drain wire to TB1-2 ground. Leave foil and drain wire
disconnected at host end of cable by cutting them off at the end of the cable jacket.
7. When using the Buffered Direct Connect ProxPro with a 20 conductor cable, DC+ and Power (Red
and White / Red wires) must have a common connection to the host +DC power supply. The two
ground wires (Black and White / Black) must have a common ground connection to the host +DC
power supply.
February 22, 2007
Page 5 of 14
© 2007 HID Global Corporation. All rights reserved.