8 Specifications
8.1
Read Distance
–
using PROXCARD II®
¾ Over all Operating Limits, minimum (@12VDC))
5.0 inches (12.7 cm)
¾ Non-Metallic Mounting, typical (@12VDC)
8.0 inches (20.3 cm)
¾ Mounted on Metal, typical (@12VDC)
5.5 inches (14 cm)
¾ Overall Operating Limits, minimum (@24VDC)
5.5 inches (14 cm)
¾ Non-Metallic Mounting, typical (@24VDC)
9.0 inches (23 cm)
¾ Mounted on Metal, typical (@24VDC)
6.0 inches (15.2 cm)
8.2
Environmental Characteristics
¾ Designed for listing under UL 294 “Standard for Access Control System Units”
¾ Operating Temperature Range
-30
o
C to 65
o
C (-22
o
F to 150
o
F)
¾ Storage Temperature Range
-40
o
C to 85
o
C (-40
o
F to 185
o
F)
¾ Operating Humidity Range
5% to 95% non-condensing
¾ Operating Vibration Limit
.04 g
2
/Hz 20-2000Hz
¾ Operating Shock Limit
30g, 11mS, Half Sine
¾ Enclosure Material
UL Recognized Lexan® Polycarbonate
¾ Weight 11.3oz
(310gms)
8.3
Power Requirements
¾ Power supply
Linear type recommended
¾ Operating Voltage Range (+DC)
10VDC -28.5VDC
¾ Maximum Average Current 12V/24V
90mA/155mA
¾ Transient Protection (all terminals)
UL 294
¾ Reverse Voltage Protection
YES
¾ Input Voltage (maximum data-0/1 lines)
28.5VDC
¾ Input Voltage (maximum interface lines)
28.5VDC
8.4
Option D – Buffered Direct Connect Keypad
¾ Operating Voltage Range (+DC)
10VDC -26VDC
¾ Input Voltage (Maximum Data – 0/1 Lines)
14VDC
¾ Input Voltage (Maximum Interface Lines)
14VDC
8.5
Operating Parameters
¾ Excitation Frequency
125KHz
¾ Duty Cycle (alternate power level rate)
20% @ 60mS period
¾ Read and Report Speed (26 bit Wiegand Card)
175mS
¾ Maximum Cable Distance to Host
500 feet (152 meters)
¾ LED Type
Bi-colored Red/Green
¾ LED Operation (host control of red/green)
<
.5V on LED control line
¾ Beeper Operation (host control)
<
.5V on beeper line
¾ LED Control (default)
internal/single
¾ Beeper Control (default)
Beeper enabled
¾ Anti-Pass Back Delay (default)
1 second
¾ Wiegand Data Pulse Widths (default)
40uS
¾ Wiegand Data Interval (default)
2mS
Page 12 of 14