SPEKTRUM DX6i • RADIO PROGRAMMING GUIDE
DUAl RATE AND EXPONENTIAl
The Dual Rate and Exponential function allows two control rates to be programmed and selected with a switch.
Dual rates and Expos are available on the aileron, elevator and rudder channels. Changing the dual rate value not
only affects the maximum control authority but also affects the overall sensitivity of control. A higher rate yields a
higher overall sensitivity. The sensitivity around center can be tailored using the Exponential function to precisely
adjust control feel.
Dual and Expo rates can be controlled by their respective dual rate switches (aileron, elevator and rudder) or by
one common switch (Aileron D/R, Elevator D/R, Rudder D/R or the Gear switch). See COMBI SWITCH screen on
page 46 for detail on combining the Dual rate switches.
Dual rate values are adjustable from 0–100%. The factory default settings for both the 0 and 1 switch positions
are 100%. Exponential values are adjustable from -100% to +100% with a factory default of 0% or inhibit. Either
switch position may be selected as the low or high rate by placing the switch in the desired position and adjusting
the value accordingly.
Note: A negative (-) Expo value will increase sensitivity around neutral, and a positive (+) Expo
value will decrease sensitivity around neutral. Normally a positive value is used to desensitize
control response around neutral.
TO ADjUST ThE DUAl AND EXPO RATES
With the transmitter already powered on and the main screen displayed, press and release the ROLLER to enter the
ADJUST LIST.