III.

Draining the system

You will need to disconnect a line from one of the lowermost components. Procure a bucket large enough to receive approximately 1
liter of fluid, and place the bucket underneath the connection that you intend to “break”. Disconnect the line, and place both ends into
the bucket.

Open up the fill-cap from the MCRES-525. This will allow most of the fluid to escape.

A cleaner and much more convenient method consists in incorporating a drain assembly into the circuit during initial installation. See

TV500

drain assembly below.

IV. Periodic

maintenance

Every 6 months: dust off the radiator fins and fan. You can use a can of compressed air for example, available in most
electronic supply stores. If you live in a very dusty area, you should perform this task at closer intervals. It is essential to
maintain the optimum performance of your cooling system.
Inspect the level of liquid inside the circuit, and refill if necessary. Evaporation in this closed circuit is extremely limited, but
still present due to permeability in the vinyl lines.

Rouchon Industries, Inc., dbA Swiftech™ – 1703 E. 28

th

St, signal Hill, CA 90755, USA – T (562) 595-12009 – F (562) 595-8769 – All content

Copyright Swiftech 2004 – Last edited 9-11-04 – Subject to revision without notice