Allied Telesis AT-MCF2012LC/1 User Manual
Page 17

AT-MCF2012LC and AT-MCF2012LC/1 Media Converter Modules Installation Guide
17
2 km (1.24 mi.) maximum operating distance using
50/125 µm or 62.5/125 µm (core/cladding) multimode
fiber optic cable for the fiber optic ports on the
AT-MCF2012LC module
20 km (12.4 mi.) maximum operating distance using
9/125 µm single-mode fiber optic cable for the fiber optic
ports on the AT-MCF2012LC/1 module
Link Test, MissingLink
™
, and Smart MissingLink
channel operating modes
Store and forward packet processing with cyclic
redundancy check (CRC)
Hot swapping support so that the module can be
installed while the chassis is powered on.
Note
The maximum operating distances of the fiber optic
ports assume full-duplex operation. A fiber optic port
operating in half-duplex mode will have a maximum
operating distance that is significantly less.
Note
The modules must be installed in an AT-MCF2000
product line chassis, such as the AT-MCF2000
chassis. For information on the availability of other
chassis models in the AT-MCF2000 product line,
contact your Allied Telesis sale representative or visit
our web site.