Allied Telesis AT-9448Ts/XP User Manual
Page 68

Chapter 3: Preparing the Switches of the Stack
68
The command lists the switches of a stack. An example is show in
Figure 30.
Figure 30. SHOW STACK Command
5. Match the entries in the table with the physical devices of the stack in
the equipment rack by referring to the labels on the front panels of the
units. The ID number and MAC address on a switch’s label should
match the unit’s entry in the table. For example, the switch labelled 2
and assigned the static module ID number 2 should correspond to
Module 2 in the table.
If there is a mismatch, you may have assigned the wrong module ID
number to a switch. To correct a problem, disconnect the stacking
cables and perform “Assigning the Static Module ID Number 1 to the
Master Switch” on page 58 or “Assigning a Static Module ID Number to
the Member Switches” on page 61 on any switch with an incorrect
module ID number. (The module ID number must be set while the
switch is functioning as a stand-alone unit.) Afterwards, reconnect the
stacking cables.
6. If the physical switches correspond correctly with the information from
the command, the stack is operating correctly. To complete the
installation, install any optional SFP and XFP fiber optic modules and
connect the network cables to the ports on the units, as explained in
Chapter 4, “Cabling the Network Ports” on page 73.
Allied Telesis Ethernet Switch AT-9448Ts/XP - AT-S63
Local Mac Addr
:0:4:75:0:0:11
Master MAC Addr
:0:4:75:0:0:11
Backup Master MAC Addr
:0:4:75:0:0:44
Topology
:None
My ModuleID
:1
ModuleID Assignment Mode
:STATIC
Current State
:Master
Module Count
:3
-----------------------------------------------------------
Module
Stack State
Model Name
Priority
Mac Address
-----------------------------------------------------------
1
Master
AT-9448Ts/XP
16
0:4:75:0:0:11
2
Member
AT-9424Ts/XP
16
0:4:75:0:0:44
3
Member
AT-9424Ts/XP
16
0:4:75:0:0:7