Installing the switches in an equipment rack – Allied Telesis AT-9448Ts/XP User Manual
Page 49

AT-9400 Stack Installation Guide
49
Installing the Switches in an Equipment Rack
Note
Installing a stack on a table or desktop is not recommended because
it may create a hazardous work area.
Perform the following procedure to install each switch in a standard
19-inch rack:
Note
Steps 1, 2, and 3 are optional. They remove the snap-on plastic feet
from the bottom of a switch. The feet can be left on.
1. Place the switch upside down on a level, secure surface.
2. Using a flat-head screwdriver, remove the snap-on plastic feet from the
bottom of the switch, as shown in Figure 14.
Figure 14. Removing the Feet
3. Turn the switch over.
4. Attach a rack-mount bracket to one side of the switch using four of the
screws that come with the switch, as shown in Figure 15.