Chapter 4: Installing the Switch and its Power Supplies

70

as this equipment.

ˆ

Switching or disconnecting devices shall not be in the earthed
circuit conductor between the DC source and the point of
connection of the earthing electrode conductor.

E55

Warning

Enough wiring space is required to allow the conductors to be
introduced and connected easily.

E56

To power on a switch with a DC AT-PWR250R-80 Power Supply Module,
review the essential safety information above and perform the following
procedure:

1. Power off the DC circuit to be used for the chassis.

2. Verify that the On/Off switch on the DC AT-PWR250R-80 Module is in

the Off position.

3. Use the legend above the terminal block to identify the terminals. The

terminals are positive, power supply ground and negative, from left
to right, as shown in Figure 32 on page 70.

Figure 32.

DC Terminal Block on the DC AT-PWR250R-80 Power Supply

Module

2205

A

A

A

T

-PWR250R

DC OUT
FAULT

+

-

6A

40-60VDC

FOR CENTRALIZED DC POWER

CONNECTION, INST

ALL ONL

Y

IN A

ON

OFF

+48 VDC Positive

Ground

-48 VDC Negative

Terminal

Terminal

Terminal