10 miscellaneous, 11 command by number – Matrix Orbital GLT240128 Legacy User Manual
Page 64

Description
Syntax
Page
Data Lock
Hexadecimal
0xFE 0xCA 0xF5 0xA0 [level]
Decimal
254 202 245 160 [level]
50
Set and Save Data Lock
Hexadecimal
0xFE 0xCB 0xF5 0xA0 [level]
Decimal
254 203 245 160 [level]
52
Dump the Filesystem
Hexadecimal
0xFE 0x30
Decimal
254 48
ASCII
254 “0”
52
Write Customer Data
Hexadecimal
0xFE 0x34 [data]
Decimal
254 52 [data]
ASCII
254 “4” [data]
52
Read Customer Data
Hexadecimal
0xFE 0x35
Decimal
254 53
ASCII
254 “5”
52
14.10
Miscellaneous
Description
Syntax
Page
Read Version Number
Hexadecimal
0xFE 0x36
Decimal
254 54
ASCII
254 “6”
53
Read Module Type
Hexadecimal
0xFE 0x37
Decimal
254 55
ASCII
254 “7”
53
14.11
Command By Number
Command Description Page
Hex
Dec
ASCII
0x21
33
“!”
Wipe Filesystem
45
0x24
36
“$”
Uploading a Font File
24
0x30
48
“0”
Dump the Filesystem
52
0x31
49
“1”
Setting the Current Font
24
0x32
50
“2”
Font Metrics
25
0x33
51
“3”
Changing the I
2
C Slave Address
19
0x34
52
“4”
Write Customer Data
52
0x35
53
“5”
Read Customer Data
52
0x36
54
“6”
Read Version Number
53
0x37
55
“7”
Read Module Type
53
0x39
57
“9”
Changing the Baud Rate
20
0x3A
58
“:”
Turn Flow Control On
18
0x3B
59
“;”
Turn Flow Control Off
19
0x42
66
“B”
Display On
40
Matrix Orbital
GLT240128
59