beautypg.com

7 set dragging threshold, 8 set pressure threshold, 9 run touchpad calibration – Matrix Orbital GLT240128 Legacy User Manual

Page 44

background image

Default

Report All

Examples

0x01

Key down values are sent on touch presses only

0x03

Key down and key up values are sent on presses and releases respectively

0x06

Key down values are reported on press and drag events

0x0F

Key down values are sent on presses and drags, key up values on releases, and 0xFF on out of

9.7

Set Dragging Threshold

Syntax

Hexadecimal

0xFE 0x89 [threshold]

Decimal

254 137 [threshold]

Parameters

Parameter

Length

Description

threshold

1

Touch pad dragging threshold,
single byte value (1 to 255).

Description

This command specifies the distance a press must be dragged moved
before a drag event is reported to the host. The lower the threshold the
more values sent to the host, while the higher the value the less precise
the drag reporting may be. Distance is calculated as
d

=

(x

2

x

1

)

2

+ (y

2

y

1

)

2

. Care should be taken to find the

appropriate balance between data points and accuracy.

Remembered

Yes

Default

8

9.8

Set Pressure Threshold

Syntax

Hexadecimal

0xFE 0x8A [threshold]

Decimal

254 138 [threshold]

Parameters

Parameter

Length

Description

threshold

2

Touch pad pressure threshold, two
byte value (1 to 65535).

Description

This command sets the presure required to be placed upon the screen
before a press event is recorded.

Remembered

Yes

Default

1000

9.9

Run Touchpad Calibration

Matrix Orbital