7 set dragging threshold, 8 set pressure threshold, 9 run touchpad calibration – Matrix Orbital GLT240128 Legacy User Manual
Page 44

Default
Report All
Examples
0x01
Key down values are sent on touch presses only
0x03
Key down and key up values are sent on presses and releases respectively
0x06
Key down values are reported on press and drag events
0x0F
Key down values are sent on presses and drags, key up values on releases, and 0xFF on out of
9.7
Set Dragging Threshold
Syntax
Hexadecimal
0xFE 0x89 [threshold]
Decimal
254 137 [threshold]
Parameters
Parameter
Length
Description
threshold
1
Touch pad dragging threshold,
single byte value (1 to 255).
Description
This command specifies the distance a press must be dragged moved
before a drag event is reported to the host. The lower the threshold the
more values sent to the host, while the higher the value the less precise
the drag reporting may be. Distance is calculated as
d
=
(x
2
− x
1
)
2
+ (y
2
− y
1
)
2
. Care should be taken to find the
appropriate balance between data points and accuracy.
Remembered
Yes
Default
8
9.8
Set Pressure Threshold
Syntax
Hexadecimal
0xFE 0x8A [threshold]
Decimal
254 138 [threshold]
Parameters
Parameter
Length
Description
threshold
2
Touch pad pressure threshold, two
byte value (1 to 65535).
Description
This command sets the presure required to be placed upon the screen
before a press event is recorded.
Remembered
Yes
Default
1000
9.9
Run Touchpad Calibration
Matrix Orbital
GLT240128
39