Description
This command turns the backlight on after the [minutes] timer has
expired, with a ninety minute maximum timer. A time of 0 specifies that
the backlight should turn on immediately and stay on. When this
command is sent while the remember function is on, the timer will reset
and begin after power up.
Remembered
Yes
Default
0
10.4
Display Off
Syntax
Hexadecimal
0xFE 0x46
Decimal
254 70
ASCII
254 “F”
Description
This command turns the backlight off immediately. The backlight will
remain off until a ’Display On’ command has been received.
Remembered
Yes
10.5
Set Brightness
Syntax
Hexadecimal
0xFE 0x99 [brightness]
Decimal
254 153 [brightness]
Parameters
Parameter
Length
Description
brightness
1
Display brightness setting (0 to
255).
Description
This command sets the display [brightness]. If the remember function is
on, this command acts the same as ’Set and Save Brightness’.
Remembered
Yes
Default
255
10.6
Set and Save Brightness
Syntax
Hexadecimal
0xFE 0x98 [brightness]
Decimal
254 152 [brightness]
Parameters
Parameter
Length
Description
brightness
1
Backlight setting (0 to 255).
Description
This command sets and saves the display [brightness] as default.
Remembered
Always
Matrix Orbital
GLT240128