3 init default setup, 4 configuration data, 5 input/output data – Horner APG SmartMod HE359THM200 User Manual
Page 2: 6 installation / safety, 7 technical support
MAN0841-03-EN
Specifications / Installation
__________________________________________________________________________________________________________________________________________________________________
5/8/2009 Page 2 of 2 ECN # 950
3
Init Default Setup
Communication parameters will be set to INIT default after performing the
procedure:
Register 40012 (Channel Enable) Bit Definition
Bit 8-15
Bit 7
Bit 6
Bit 4
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Unused
Input 7
Input 6 Input 5
Input 4
Input 3
Input 2
Input 1
Input 0
0 = Disable Input
1 = Enable Input
1. Install jumper between INIT and GND terminals of the RS-485 port.
2. Apply power to Smartmod unit.
3. Read parameter words to see current parameters.
4. Write changes if necessary.
5 Input/Output
DATA
INIT
D-
D+
GND
A
B
C
D
SmartMod Analog I/O utilizes both Modbus Registers (40001-40030) and Coils (1-11). It is possible
to access all data using Registers only, because the Coils can be accessed through Register 40010.
The following tables lists all Modbus I/O data available.
I/O Register Data (Registers 40014-40022)
Modbus
Register
Description Access
Minimum
Maximum Units
40010
Mirror of Coil
Data
Read/Write n/a
n/a
n/a
40014
Cold Junction
Temperature
Read-only
-1000
6000
0.01 degrees C
40015
Input 0
Read-only
0.1C or 0.001mV
40016
Input 1
Read-only
0.1C or 0.001mV
40017
Input 2
Read-only
0.1C or 0.001mV
40018
Input 3
Read-only
0.1C or 0.001mV
40019
Input 4
Read-only
0.1C or 0.001mV
40020
Input 5
Read-only
0.1C or 0.001mV
40021
Input 6
Read-only
0.1C or 0.001mV
40022 Input
7 Read-only
Depends
on Input
Type
Depends
on Input
Type
0.1C or 0.001mV
The INIT Default RS485 Settings Are:
Modbus ID = 1
Baud rate = 9600
Parity = None
Stop Bits = 1
Data Bits = 8
No handshake
Note: There are 2 types of default settings possible:
1. Factory default as described in section 1 (Specifications)
2. Default after INIT as described in section 3 (INIT Default Setup)
4 Configuration
DATA
SmartMod Configuration settings are mapped into Modbus Register space.
This configuration data may be modified with any Modbus/RTU Master device.
For convenience, Horner APG has developed a variety of Cscape application
files which allow an OCS (Xle, NX, LX, QX) to act as a SmartMod configurator.
Initial configuration of SmartMod module should be done on an individual
basis, since all modules come from the factory with a default Modbus ID of 1.
Once each module on the network has its own unique Modbus ID, further
configuration adjustments can be made with the entire network powered.
All configuration parameters listed below (except 40012 Channel Enable) are
stored in EPROM. That means they should not be constantly rewritten.
Configuration Parameters – Registers 40001 through 40013
Modbus
Register
Description Min
Max
Default
40001-
40005
Reserved
40006
Communications
Parameters
See Table
38.4kbaud,
N, 8, 1, RTU
Mode
40007 Modbus
ID
1
255
1
40008
Rx/Tx Delay (in 2mS
steps)
0 255
0mS
40009
Watchdog Timer (in 0.5s
steps)
0 255 10
(5s)
40010
Modbus Coil Data
Not Configuration Data – See
I/O Data
40011
Input Type
See Table
1 (+/- 50 mV)
40012
Channel Enable
See Table
255
(Channels
1-8 enabled)
40013 Reserved
Modbus
Coil
Description
Access
Watchdog Event & Power-up
Event Operation
00001
Open Detect Input 0
Read/Write
00002
Open Detect Input 1
Read/Write
00003
Open Detect Input 2
Read/Write
00004
Open Detect Input 3
Read/Write
00005
Open Detect Input 4
Read/Write
00006
Open Detect Input 5
Read/Write
00007
Open Detect Input 6
Read/Write
00008
Open Detect Input 7
Read/Write
00009 Watchdog
Enabled Read/Write
00010 Watchdog
Event Read/Write
00011 Power-up
Event Read/Write
If Coil 9 (Watchdog Enabled) is set,
Coil 10 (Watchdog Event) will set if
the Watchdog Timeout value is
exceeded. The Watchdog Timeout
value is set in Register 40009.
When set, Coil 10 can be reset by
the controller when normal
communications resumes.
The Power-up Event (Coil 11) is set
every time the power is applied. It
can be cleared by the controller if
desired.
6
Installation / safety
Warning: Remove power from the OCS controller, CAN port, and any peripheral equipment
connected to this local system before adding or replacing this or any module.
a. All applicable codes and standards should be followed in the installation of this product.
b. Shielded, twisted-pair wiring should be used for best performance.
c. Shields may be terminated at the module terminal strip.
d. In severe applications, shields should be tied directly to the ground block within the panel.
e. Use the following wire type or equivalent: Belden 8441.
For detailed installation and a handy checklist that covers panel box layout requirements and
minimum clearances, refer to the hardware manual of the controller you are using.
When found on the product, the following symbols specify:
Register 40006 (Communications Parameters) Bit Definition
Bits 7-15
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Warning: Electrical
Shock Hazard.
Warning: Consult
user documentation.
Unused Mode
Parity
Data
Bits
Baud Rate
Value Meaning
Value
Meaning
0 Mark
0 1200
baud
0 =
ASCII
Mode
1 Even
0 = 7
Data
Bits
1 2400
baud
2 Odd
2 4800
baud
3 Space
3 9600
baud
1 =
RTU
Mode
1 = 8
Data
Bits
4 19200
baud
5-7
38400
baud
7 Technical
Support
Technical Support at the following locations:
North America:
Tel: 317 916-4274
Fax: 317 639-4279
Web:
Email:
Europe:
Tel: +353-21-4321266
Fax: +353-21-4321826
Web:
Email:
Register 40011 (Input Type) Value Definition
Value
Input Type
Value
Input Type
1
+/-50mV
14
Type J T/C
2
+/-100mV
15
Type K T/C
3
+/-250mV
16
Type T T/C
4
+/-1000mV
17
Type E T/C
5-13
Not Used
18
Type R T/C
19
Type S T/C
20
Type B T/C
21
Type N T/C
No part of this publication may be reproduced without the prior agreement and written
permission of Horner APG, Inc. Information in this document is subject to change without
notice.