Aalborg TIO Totalizer I/O Flow Monitor/Controller User Manual
Page 90
87
COMMAND
NAME
DESCRIPTION
NO.
COMMAND SYNT
A
X
COMMAND
ARGUMENT 1
ARGUMENT 2
ARGUMENT 3
ARGUMENT 4
RESPONSE
Signal
Conditioner
Settings
Sets/Reads Signal Conditioner
Parameters
Argument1 = F:
Display/Change NR Filter
Parameters:
NRF Sample Number [1-32]
NRF T
ime Limit [0-199]
NRF Error Limit [0.0-10.0%]
16
SC
M
Read/Change Device
Signal Conditioner
Mode
N – No Conditioning
F – NRF Filter
A – Running A
verage
[N, F
, A]
SCM:
Example:
SCM:F
No Argument
(Returns Current
Mode)
SCM:
Example:
SCM:F
D
Flow Running
A
verage Damping
[0-500 ms]
0 - Disabled
in ms [0-500]
SCD:
Example: SCD:50
No Argument
(Returns Current set.)
PWD:
Example: SCD:50
F
NR Filter Settings:
NRF Sample Numb.
NRF T
ime Limit
NRF Error Limit
Sample#
[1-32]
T
ime Limit
[0-199]
Error Limit
[0.0-10%]
Example:
PWF:4,8,0.0
No Argument
(Returns Current
set.)
Example:
PWF:4,8,0.0
L
Device Flow
Linearizer
E- Enable
D- Disable
alue> E or D SCL: Example: SCL:E No Argument (Ret. Current settings) SCL: Example: SCL:E