Module Compatibility and Valve Settings:
Valve Type
Coil
Voltage
(V)
IMin
(mA)
IMax
(mA)
Dither
Frequency
(Hz)
Dither
Amplitude
(%)
PSL/V – (Size 2)
12
~450 mA
~1,160 mA
40 - 70 Hz (55)
20 - 35%
PSL/V – (Size 2)
24
~225 mA
~580 mA
40 - 70 Hz (55)
20 - 35%
PSL/V(F) – (Sizes 3 & 5)
12
~620 mA
~1,260 mA
40 - 70 Hz (55)
20 - 35%
PSL/V(F) – (Sizes 3 & 5)
24
~310 mA
~630 mA
40 - 70 Hz (55)
20 - 35%
EM 21 D(S)E
12
~50 mA
~1,200 mA
50 - 150 Hz
20 - 40%
EM 21 D(S)E
24
~25 mA
~630 mA
50 - 150 Hz
20 - 40%
EMP 21 S
12
~550 mA
~1,100 mA
50 - 150 Hz
20 - 40%
EMP 21 S
24
~240 mA
~480 mA
50 - 150 Hz
20 - 40%
EMP 21 V
12
~500 mA
~1,000 mA
50 - 150 Hz
20 - 40%
EMP 21 V
24
~200 mA
~500 mA
50 - 150 Hz
20 - 40%
EMP 21 S10
12
~40 mA
~1,300 mA
50 - 150 Hz
20 - 40%
EMP 21 S10
24
~20 mA
~650 mA
50 - 150 Hz
20 - 40%
EMP 21 V10
12
~400 mA
~1,380 mA
50 - 150 Hz
20 - 40%
EMP 21 V10
24
~200 mA
~690 mA
50 - 150 Hz
20 - 40%
EMP 31 S
12
~240 mA
~1,200 mA
50 - 150 Hz
20 - 40%
EMP 31 S
24
~120 mA
~600 mA
50 - 150 Hz
20 - 40%
EMP 31 V
12
~400 mA
~1,000 mA
50 - 150 Hz
20 - 40%
EMP 31 V
24
~200 mA
~500 mA
50 - 150 Hz
20 - 40%
EMP 31 S10
12
~150 mA
~1,200 mA
50 - 150 Hz
20 - 40%
EMP 31 S10
24
~75 mA
~600 mA
50 - 150 Hz
20 - 40%
EMP 31 V10
12
~400 mA
~1,560 mA
50 - 150 Hz
20 - 40%
EMP 31 V10
24
~200 mA
~780 mA
50 - 150 Hz
20 - 40%
EMP 41 S
12
~100 mA
~870 mA
50 - 150 Hz
20 - 40%
EMP 41 S
24
~200 mA
~1,750 mA
50 - 150 Hz
20 - 40%
EMP 41 V
12
~100 mA
~870 mA
50 - 150 Hz
20 - 40%
EMP 41 V
24
~200 mA
~1,750 mA
50 - 150 Hz
20 - 40%
PMV
12
~200 mA
~1,260 mA
60 - 150 Hz
20 - 40%
PMV
24
~100 mA
~630 mA
60 - 150 Hz
20 - 40%
PDM, PDV
12
~190 mA
~1,200 mA
50 - 150 Hz
20 - 40%
PDM, PDV
24
~110 mA
~680 mA
50 - 150 Hz
20 - 40%
PM(Z)
12
~200 mA
~1,260 mA
50 - 150 Hz
20 - 40%
PM(Z)
24
~100 mA
~630 mA
50 - 150 Hz
20 - 40%
SE - (Sizes 2 & 3)
12
~380 mA
~1,900 mA
60 - 150 Hz
20 - 40%
SE - (Sizes 2 & 3)
24
~190 mA
~950 mA
60 - 150 Hz
20 - 40%
SEH - (Sizes 2 & 3)
12
~250 mA
~1,260 mA
60 - 150 Hz
20 - 40%
SEH - (Sizes 2 & 3)
24
~130 mA
~630 mA
60 - 150 Hz
20 - 40%
SWS 2
12
~400 mA
~1,350 mA
50 - 150 Hz
20 - 40%
SWS 2
24
~260 mA
~880 mA
50 - 150 Hz
20 - 40%
V30D "V" Controller
24
~250 mA
~750 mA
80 - 100 Hz
20 - 40%
Note: Final optimized settings are valve size and system/application dependent. Consult valve manufacturer for full details
as required
.