Control logic – High Country Tek PLD, Powerline / universal single / dual coil PWM Valve Driver User Manual
Page 18
Part No:-
021-00155 RevD7
PowerLine System Controller User Guide
Page | 18
PowerLine User Guide
Selection from Menu ->
Restore Temporary Memory from Permanent Memory
Restores settings stored in permanent memory to temporary (operational) memory.
Caution:
Use of this selection temporarily prevents the unit from working in the system.
Do not select this option while the machine is operating.
Selection from Menu ->
Restore Temporary & Permanent
Memory from a File
When this selection is made, the user is prompted for a file
name and location from which to retrieve settings. The
restored values are placed in temporary and permanent
memory.
Caution:
Use of this selection temporarily prevents the
unit from working in the system.
Do not select this option while the machine is operating.
Control Logic:
This drop down menu allows the user to
select what control mode the controller will
operate in:
1. Manual PWM control
( Set-up )
2. Anti-Stall
(Reverse option available)
3. Anti-Stall with Max Command
4. Valve Control
( Single or dual coil )
IMPORTANT NOTE – DUAL COIL OPERATION:
The output of either ‘A’ or ‘B’ output will go from the respective ‘I Min’ setting to ZERO (0mA ) when crossing
through command mid-point. The valve outputs do NOT jump from one I Min to the other.