Dsplay, 3 module 3 - d, Yes selsenb – Red Lion CUB5T User Manual
Page 9: Yes rstsenb, No d-scroll, Red d-color, 5d-level, 000 proscode, Mo factsset, Isplay

9
The
yES
selection allows the
SEL
button to toggle between the timer and cycle
counter displays.
FRONT PANEL DISPLAY SELECT ENABLE (SEL)
6.3 MODULE 3 - D
ISPLAY
AND
F
RONT
P
ANEL
K
EY
P
ARAMETERS
(
3-dSPLAY
)
SEL
Pro
Backlight Unit Only
Front Panel
Reset Enable
Front Panel
Display
Select
Display Scroll
Enable
Load Factory
Default
Settings
Display
Color
Programming
Security
Code
Display
Intensity
Level
3-dSPLAY
SEL Enb
RSt Enb
d-ScroLL
d-COLOr
d-LEVEL
Pro CodE
FACt SEt
PARAMETER MENU
The
yES
selection allows the
RST
button to reset the selected value(s). The
shaded selections only appear if the cycle counter is enabled.
FRONT PANEL RESET ENABLE (RST)
The
yES
selection allows the display to automatically scroll between the timer
and cycle counter values. The scroll rate is about every 4 seconds.
DISPLAY SCROLL ENABLE
Enter the desired display color, red or green. This parameter is active for
backlight units only.
DISPLAY COLOR (BACKLIGHT UNIT ONLY)
Enter the desired Display Intensity Level (1-5). The display will actively dim
or brighten as levels are changed. This parameter is active for backlight units only.
DISPLAY INTENSITY LEVEL (BACKLIGHT UNIT ONLY)
The Security Code determines the programming mode and the accessibility
of programming parameters. This code can be used along with the Program
Mode Lock-out (
Pro Loc
) in the User Input Function parameter (Module 1).
Two programming modes are available. Full Programming mode allows all
parameters to be viewed and modified. Quick Programming mode permits only
the Setpoint values and Timer Stop value to be modified, but allows direct
access to these values without having to enter Full Programming mode.
Programming a Security Code other than 0, requires this code to be entered
at the
Pro CodE
prompt in order to access Full Programming mode. Depending
on the code value, Quick Programming may be accessible before the
Pro CodE
prompt appears (see chart).
PROGRAMMING SECURITY CODE
The
yES
selection will return the meter to the factory default settings. The
meter will display
rESEt
and then return to
Pro
, at which time all settings have
been changed.
Pressing the
RST
key on power-up will load the factory settings and display
rESEt
. This allows operation in the event of a memory failure or corrupted data.
LOAD FACTORY DEFAULT SETTINGS
NO
yES
C-VALUE
both t-C
dSPLAy
yES
NO
NO
t-VALUE
NO
yES
6rn
rEd
0
to
999
yES
NO
yES
SELsEnb
YES
RStsEnb
NO
d-ScroLL
rEd
d-COLOr
5
d-LEVEL
000
ProsCodE
MO
FACtsSEt
1
to
5
USER INPUT
FUNCTION
USER INPUT
STATE
SECURITY
CODE
FULL PROGRAMMING
MODE ACCESS
0
Full Programming
Immediate Access
not
Pro Loc
______
1-99
Quick
Programming
100-999
Pro CodE
prompt
With correct code entry at
Pro CodE
prompt *
0
Programming
Lock
No Access
Active
1-99
Quick
Programming
No Access
Pro Loc
100-999
Pro CodE
prompt
With correct code entry at
Pro CodE
prompt *
Not Active
0-999
Full Programming
Immediate Access
After Quick Programming
with correct code entry at
Pro CodE
prompt *
MODE WHEN “SEL”
KEY IS PRESSED
* Entering Code 222 allows access regardless of security code.