Enter the probe burn-out action. In the event of a temperature probe failure

(open), the output can be programmed to be on or off.

PROBE BURN-OUT ACTION

ON

OFF

This parameter enables the backlight CUB5 to switch the backlight color when

the output state changes. This parameter is only active for the backlight version.

CHANGE DISPLAY COLOR w/OUTPUT STATE

YES

NO

LIMITED WARRANTY

The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years

from the date of shipment, provided the products have been stored, handled, installed, and used under proper conditions. The

Company’s liability under this limited warranty shall extend only to the repair or replacement of a defective product, at The

Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the products.
The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses

arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal

injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to

any extent liable, including without limitation penalties imposed by the Consumer Product Safety Act (P.L. 92-573) and liability

imposed upon any person pursuant to the Magnuson-Moss Warranty Act (P.L. 93-637), as now in effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except those expressly contained herein.

The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations.

SEL

Data Bit

Baud Rate

Parity Bit

Print

Options

Meter

Address

Abbreviated

Printing

5-SEr

bAUd

dAtA

PAr

Addr

Abbr

OPt

Pro

The Serial Setup Parameters are only active when one of the optional serial communications/programming cards is installed in the meter.

Refer to the CUB5COM bulletin for details and setup for the CUB5 RS232 or RS485 serial communications.

Refer to the CUB5USB bulletin for details on the CUB5 USB programming and programming requirements.

PARAMETER MENU

This parameter enables the

RST

button or user input to reset the output when

the display is reset.

Note: For this parameter to operate, the

RST

button or User Input being used

must be set to

dSP

and the Input value must be displayed. If these conditions are

not met, the output will not reset.

YES

rEn-n

OUTPUT RESET WITH DISPLAY RESET

YES

NO

When

YES

, the output is disabled (after a power up) until the trigger point is

crossed. Once the output is on, the output operates normally per the Setpoint

Action and OutputReset Action.

NO

Stb-n

STANDBY OPERATION

YES

NO

When the user input or

RST

button is activated (momentary action), the

corresponding “on” output is reset immediately and remains off until the

trigger point is crossed again. (Previously latched alarms will be off if power

up Display Value is lower than setpoint value.)

L-dLY

= Latch with delay reset action; This action latches the output on at the

trigger point per the Setpoint Action shown in Setpoint Output Figures. Latch

means that the output can only be turned off by the front panel

RST

button

or user input manual reset, serial reset command or meter power cycle. When

the user input or

RST

button is activated (momentary action), the meter

delays the event until the corresponding “on” output crosses the trigger off

point. (Previously latched outputs are off if power up Display Value is lower

than setpoint value. During a power cycle, the meter erases a previous

L-dLY

reset if it is not activated at power up.)

OUTPUT

STATE

OFF

ON

Hys

SP

Auto

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

MANUAL

RESET

LAtCH

L-dLY

SP - Hys

( )

( )

( )

{

Setpoint Output Reset Actions

NO

ChC-n

OFF

brn-n