Input, 1 module 1 - i, Cnt ud inp a-b – Red Lion CUB5 User Manual

Page 7: 0cnta dp, 0000 cmta scf, No cmtb bat, 0cntb dp, No rst p-up, Cntb scf, Nor cmta dir

background image

7

6.1 Module 1 - i

nput

S

etup

p

araMeterS

(

1-INPUt

)

COUNTER A DECIMAL POSITION

COUNTER A SCALE FACTOR

The number of input counts is multiplied by the scale factor to obtain the

desired process value. A scale factor of 1.0000 will result in the display of the

actual number of input counts. (Details on scaling calculations are explained at

the end of this section.)*

This selects the decimal point position for Counter A. The selection will also

affect Counter A scale factor calculations.

00.0001

to

99.9999

COUNTER RESET AT POWER-UP

yES

NO

COUNT MODE

Select the count mode that corresponds with your application. The input

actions are shown in the boxes below. For simple counting applications, it is

recommended to use Count with Direction for the count mode. Simply leave the

direction input unconnected.

COUNTER B DECIMAL POSITION

This selects the decimal point position for Counter B. The selection will also

affect Counter B scale factor calculations.

COUNTER B SCALE FACTOR

The number of input or batch counts is multiplied by the scale factor to

obtain the desired process value. A scale factor of 1.0000 will result in the

display of the actual number of input or batch counts. (Details on scaling

calculations are explained at the end of this section.)*

00.0001

to

99.9999

Count b

NO

both A-b

Count A

Cnt ud

qUAd 1

Add Add

dUAL Cnt

RAtE Cnt

qUAd 4

qUAd 2

Add Sub

0.00000

0.000

0.0

0.0000

0.00

0

0.00000

0.000

0.0

0.0000

0.00

0

Cnt ud

INP A-b

0

CntA dP

01.0000

CmtA ScF

COUNTER A COUNT LOAD VALUE

Counter A resets to this value if Reset to Count Load action is selected.

-9999999

to

99999999

00000500

CmtA Ld

COUNTER B BATCH COUNT ENABLE

The Counter B batch count function internally counts the number of output

activations of the selected setpoint(s). The count source for the batch counter

can be SP1, SP2 or both. Batch counting is available in all count modes except

Dual Counter, which uses an external input signal for Counter B. This

parameter only appears if a Setpoint Output option card is installed.

NO

Cmtb bAt

0

Cntb dP

01.0000

NO

RSt P-UP

Shaded area selections only apply when Counter B is enabled (Dual Counter

mode or batch counter).

Counter A Subtract

Counter A Add

Counter A Add

Counter A Add

Quad A

Count A

Quad A

Count A

Quad A

Count A

Counter B Add

Counter A Add

Counter A Add

Rate only

Counter A Direction

Counter A

INPUT B ACTION

INPUT A ACTION

Add Sub

2 Input Add/Subtract

Add Add

2 Input Add/Add

qUAd 4

Quadrature x4

qUAd 2

Quadrature x2

qUAd 1

Quadrature x1

dUAL Cnt

Dual Counter

RAtE Cnt

Rate/Counter

Cnt ud

Count with Direction

DISPLAY

MODE

The selected counter(s) will reset at each meter power-up.

* For value entry instructions, refer to selection/value entry in the Programming

The Meter section.

Note: The Rate indicator signal is derived from Input A in all count modes.

Cntb ScF

COUNTER A RESET ACTION

When Counter A is reset, it returns to Zero or Counter A Count Load value.

This reset action applies to all Counter A resets, except a setpoint generated

Counter Auto Reset programmed in Module 4.

to 2Ero

CmtA rSt

to 2Ero

to CtLd

COUNTER A COUNT DIRECTION

Reverse (

rEV

) switches the normal Counter A count direction shown in the

Count Mode parameter chart.

NOr

CmtA dir

NOr

rEV

NO

SP2

SP1

SP1-2

Counter A

Decimal Point

Counter A

Scale Factor

User Input

Function

Counter B

Decimal Point

Counter B

Scale Factor

Counter Reset

at Power-up

User Input

Assignment

Count

Mode

SEL

Dual Count or Batch

Only

Dual Count

or Batch

Only

INP A-b

CntA dP

CntA ScF

Cntb ScF

RSt P-UP

USEr INP

USEr ASN

1-INPUt

Pro

CntA dir

Counter A

Count

Direction

Counter A

Reset Action

CntA rSt

CntA Ld

Counter A

Count Load

Value

Counter B

Batch Count

Enable

Cntb bAt

Cntb dP

PARAMETER MENU