The Security Code determines the programming mode and the accessibility

of programming parameters. This code can be used indepentently or along with

the Program Mode Lock-out (

Pro Loc

) selection in the User Input Function

parameter (Module 1).

Two programming modes are available. Full Programming mode allows all

unit parameters to be viewed and modified. Quick Programming mode permits

only user selected values to be modified, but allows direct access to these values

without having to enter Full Programming mode.

Entering a Security Code from 1-99 enables Quick Programming mode, and

displays a sublist to select what values appear in the Quick Programming menu.

All applicable values set to

YES

in the sublist will be accessible in Quick

Programming. The sublist includes Setpoint values (

SP1 VAL

,

SP2 VAL

), Output

Time-out values (

SP1 tOUt

,

SP2 tOUt

), Counter A Count Load value (

CntA Ld

) and

the Display Intensity Level (

d-LEVEL

) for backlight units.

Programming any Security Code other than 0, requires this code to be entered

at the

Pro CodE

prompt in order to access Full Programming mode. Quick

Programming mode, if enabled, is accessed before the

Pro CodE

prompt.

PROGRAMMING SECURITY CODE

The

yES

selection will return the meter to the factory default settings. The

meter will display

rESEt

and then return to

Pro

, at which time all settings have

been changed.

LOAD FACTORY DEFAULT SETTINGS

0

to

999

yES

NO

000

Pro CodE

MO

FACt SEt

* Entering Code 222 allows access regardless of security code.

The

yES

selection allows the

SEL

button to toggle through the enabled

displays.

FRONT PANEL DISPLAY SELECT ENABLE (SEL)

The

yES

selection allows the

RST

button to reset the selected counter(s). The

shaded selections are only active when Counter B is enabled (Dual Count mode

or batch counter).

FRONT PANEL COUNTER RESET ENABLE (RST)

The

yES

selection allows the display to automatically scroll through the

enabled displays. Each display is shown for 4 seconds.

DISPLAY SCROLL ENABLE

NO

yES

Count b

both A-b

dSPLAy

yES

NO

NO
Count A

NO

yES

yES

SEL Enb

YES

RSt Enb

NO

d-ScroLL

Enter the desired display color, red or green. This parameter is active for

backlight units only.

DISPLAY COLOR (BACKLIGHT UNIT ONLY)

6rn

rEd

rEd

d-COLOr

Enter the desired Display Intensity Level (1-5). The display will actively dim

or brighten as levels are changed. This parameter is active for backlight units only.

DISPLAY INTENSITY LEVEL (BACKLIGHT UNIT ONLY)

5

d-LEVEL

1

to

5

Select

YES

to momentarily display the meter software version before advancing

to the next parameter. The software version is also displayed at power-up.

SOFTWARE VERSION DISPLAY

NO

CodE UEr

6.3 Module 3 - d

iSplay

and

f

ront

p

anel

K

ey

p

araMeterS

(

3-dSPLAY

)

SEL

Pro

Front Panel

Counter

Reset Enable

Front Panel

Display Select

Enable

Display Scroll

Enable

Load Factory

Default

Settings

Display

Color

Programming

Security

Code

Display

Intensity

Level

Backlight Unit Only

3-dSPLAY

SEL Enb

RSt Enb

d-Scro

L

L

L

L

d-COLOr

d-LEVEL

Pro CodE

FACt SEt

CodE UEr

Software

Version

Display

PARAMETER MENU

NO

yES

Immediate Access

Full Programming

0-999

Not Active

With correct code entry at

Pro CodE

prompt *

Pro CodE

prompt

100-999

Pro Loc

No Access

Quick

Programming

1-99

Active

No Access

Programming

Lock

0

With correct code entry at

Pro CodE

prompt *

Pro CodE

prompt

100-999

After Quick Programming

with correct code entry

at

Pro CodE

prompt *

Quick

Programming

1-99

______

not

Pro Loc

Immediate Access

Full Programming

0

FULL PROGRAMMING

MODE ACCESS

MODE WHEN “SEL”

KEY IS PRESSED

SECURITY

CODE

USER INPUT

STATE

USER INPUT

FUNCTION