beautypg.com

3 input wiring, 4 setpoint (output) wiring, 5 serial communication wiring – Red Lion CUB5 User Manual

Page 5: 6 usb programming, Com n.o. n.c, Single setpoint relay plug-in card, Electrical connections, Ac inputs from tach generators, etc, Two wire proximity, current source, Magnetic pickup

background image

+9-28 VDC

PWR COMMON

1

ON

*

4

2 3

INP

B

INP COMM

US

R

INP

A

MAGNETIC PICKUP

5

4.3 INPUT WIRING

CAUTION: Power common (PWR COMMON) is NOT isolated from input common (INP COMM). In order to preserve the safety of the meter

application, the power common must be suitably isolated from hazardous live earth referenced voltage; or input common must be at protective earth

ground potential. If not, hazardous voltage may be present at the Signal or User Inputs and input common terminals. Appropriate considerations must

then be given to the potential of the input common with respect to earth ground; and the common of the plug-in cards with respect to input common.

Resistor to Limit Current

to 2.5 mA MAX.

PWR COMMON

1 2

ON

4

3

*

*

INP COMM

US

R

+9-28 VDC

AC

INP

B

INP

A

*

4

PWR COMMON

2 3

*

2.2 k Ω

+9-28 VDC

INP COMM

INP

B

US

R

INP

A

ON

1

+9-28 VDC

NPN

O.C.

PWR COMMON

1

ON

*

4

*

2 3

INP

B

INP COMM

US

R

INP

A

PWR COMMON

1 2 3

ON

*

4

*

INP COMM

+9-28 VDC

O.C.

PNP

US

R

INP

B

INP

A

+9-28 VDC

+5 V

COMMON

INP COMM

INP

B

US

R

INP

A

*

4

PWR COMMON

1

ON

2 3

+9-28 VDC

PWR COMMON

1

ON

4

2 3

*

*

INP

B

INP COMM

US

R

INP

A

PWR COMMON

1 2

4

3

ON

*

*

INP COMM

US

R

+9-28 VDC

INP

B

INP

A

AC Inputs From Tach Generators, Etc.

Input A

Two Wire Proximity, Current Source

Input A

Magnetic Pickup

Input A

Current Sourcing Output

Input A

Interfacing With TTL

Input A

Current Sinking Output

Input A

Switch or Isolated Transistor; Current Sink

Input A

+9-28 VDC

4

PWR COMMON

1 2 3

ON

INP COMM

INP

B

US

R

INP

A

Switch or Isolated Transistor; Current Source

Input A

Switch position is application dependent.

Current Sink Output; Quad/Direction

Shaded areas not recommended for counting applications.

4.4 SETPOINT (OUTPUT) WIRING

COM

N.C.

N.O.

SINGLE SETPOINT RELAY PLUG-IN CARD

COM

N.O.

N.C.

ELECTRICAL CONNECTIONS

DUAL SETPOINT N-FET OPEN DRAIN PLUG-IN CARD

COM

OSNK 1(2)

(30 V MAX.)

ELECTRICAL CONNECTIONS

OSNK1

OSNK2

COM

Note: Output Common is not isolated from DC Power Common. Load must

be wired between OSNK terminal and V+ of the load supply.

4.5 SERIAL COMMUNICATION WIRING

N/

C

RS485

2

COMM

A+

B-

N/

C

5

3

4

N/

C

RS232

5

N/

C

TX

N/

C

4 3

COMM

COMM

2

RX

6

1

6

1

4.6 USB PROGRAMMING

USB PROGRAMING PLUG-IN CARD

SERIAL COMMUNICATIONS PLUG-IN CARD