beautypg.com

Configuring communications, Setting the transmitter id – DAVIS Wireless Temp/Hum Station Fan Asp., 2003 & newer User Manual

Page 8

background image

Page 8

Wireless Temperature/Humidity Station

Configuring Communications

Each wireless transmitting station must be set to one of eight DavisTalk transmitter IDs,
and each station must use a unique transmitter ID. Use the transmitter ID switches #1, 2
and 3 to set the station’s ID. Switch #4 is only used for transmission testing.

Note: The transmitter and receiver communicate with each other only when both are set

to the same DavisTalk ID.

Setting the Transmitter ID

The factory default transmitter ID is “1”. Looking at the table shown below you can see
that means the transmitter ID switches are in the OFF position when each transmitting
station leaves the factory.

Your Fan-Aspirated Temp/Hum Station requires a different DavisTalk transmitter ID
than your Integrated Sensor Suite (ISS) or any other DavisTalk-compatible wireless sta-
tion you may be using.

Use a ballpoint pen or paper clip to toggle DIP switches #1, 2, and 3. The settings for
transmitter IDs 1 – 8 are shown in the following table:

.

DIP Switches in Top-right Corner of SIM (Illustration has been enlarged for clarity)

ID C

ODE

S

WITCH

1

S

WITCH

2

S

WITCH

3

#1

(default)

off

off

off

#2

off

off

ON

#3

off

ON

off

#4

off

ON

ON

#5

ON

off

off

#6

ON

off

ON

#7

ON

ON

off

#8

ON

ON

ON

1 2 3 4

ON

Battery Holder

Antenna

Transmitter ID
Switches

Test Indicator LED