beautypg.com

Printing the configuration label, Figure 20 - configuration print sample – AMT Datasouth 4000 User Manual

Page 27

background image

User's Guide 27

Printing the Configuration Label

1. Power off the printer.

2. Make sure that 4 inch wide media is installed. The Self-test will print the maximum width of

the installed label.

3. Press and hold the FEED/Config button.

4. Power on the printer.

5. Release the FEED/Config button when the media begins to feed.

NOTE: The following figure is an example configuration printout. The feature setting on

your printer may vary based on any setup changes made or firmware version
installed in the printer.

Figure 20 - Configuration Print Sample

Media Type

Thermal Transfer

Media Sensing

Gap

Sensor Threshold

70

Media Length

4.00 Inches

Media Width

4.00 Inches

Present Distance

+0.24 Inches

Present Sensor

Disabled

Vert Print Align

0.00 Inches

Horz Print Align

+0.20 Inches

Vert Size Adjust

0

Print Darkness

-8

Print Speed

6

Interface Select

Auto Select

COM1: Baud Rate

9600

COM1: Parity

None

COM1: Data Bits

8

COM1: Handshake

RTS & XON

COM1: PAL Xmit

Disabled

Emulation Mode

PAL Emulation

Date

Not Installed

Time

Not Installed

Daylight Saving

Disabled

Firmware Rev.

110152 B

Max Media Length

12.00 Inches

Keypad Lockout

Disabled

Label Count

582

Drive A:

131072

Drive B:

262144

Drive C:

0

Drive D:

32768