Printing the configuration label, Figure 20 - configuration print sample – AMT Datasouth 4000 User Manual
Page 27
User's Guide 27
Printing the Configuration Label
1. Power off the printer.
2. Make sure that 4 inch wide media is installed. The Self-test will print the maximum width of
the installed label.
3. Press and hold the FEED/Config button.
4. Power on the printer.
5. Release the FEED/Config button when the media begins to feed.
NOTE: The following figure is an example configuration printout. The feature setting on
your printer may vary based on any setup changes made or firmware version
installed in the printer.
Figure 20 - Configuration Print Sample
Media Type
Thermal Transfer
Media Sensing
Gap
Sensor Threshold
70
Media Length
4.00 Inches
Media Width
4.00 Inches
Present Distance
+0.24 Inches
Present Sensor
Disabled
Vert Print Align
0.00 Inches
Horz Print Align
+0.20 Inches
Vert Size Adjust
0
Print Darkness
-8
Print Speed
6
Interface Select
Auto Select
COM1: Baud Rate
9600
COM1: Parity
None
COM1: Data Bits
8
COM1: Handshake
RTS & XON
COM1: PAL Xmit
Disabled
Emulation Mode
PAL Emulation
Date
Not Installed
Time
Not Installed
Daylight Saving
Disabled
Firmware Rev.
110152 B
Max Media Length
12.00 Inches
Keypad Lockout
Disabled
Label Count
582
Drive A:
131072
Drive B:
262144
Drive C:
0
Drive D:
32768