Figure 2-15 menu – calibration (cal) – EOTech MTM Mini-Thermal Monocular User Manual
Page 42
2-22
2.16 MAIN MENU – Continued
Calibration (CAL)
The system menu provides one method of calibrating the
WTM. See section 2.9 for a more detailed description of the
calibration procedures.
NOTE
Failure to cover the objective lens prior to
calibrating the WTM may result in a distorted
picture or the presence of ghost images in the
eyepiece display.
Calibrating the WTM via the system menu is accomplished
as follows:
1. Install the objective lens cover over the objective lens.
2. Activate the CAL menu item as shown below.
3. The message “CALIBRATING” will appear as the unit
performs the calibration. Once complete (< 3 seconds),
the message will disappear and the WTM will revert to
normal viewing mode.
4. Remove the objective lens cover.
Figure 2-15 Menu – Calibration (CAL)