2.9 CALIBRATION

After prolonged use, or after transitions from one

temperature extreme to another, a degradation of the

thermal image may be noticed. In these instances, and

during initial startup, the WTM should be calibrated to

optimize the viewed thermal image.

Calibration is accomplished by simultaneously pressing (and

holding) the

UP / DOWN buttons, or via the system menu

(see section 2.16, Calibration (CAL)). Regardless of which

method is used, the objective lens cover must first be placed

over the objective lens. Failure to do so may result in a

distorted picture or the presence of ghost images in the

eyepiece display.

The WTM is equipped with an internal sensor that detects

significant changes in temperature. When this condition

occurs, the message “RECAL” will appear in the eyepiece

display indicating that the operator should calibrate the WTM

as described above.

2.10 DIOPTER ADJUSTMENT

The eyepiece may be focused to accommodate differences

in individual operators’ eyesight. Diopter adjustments may

be made as follows:

1. With the system powered on, press the

PWR button to

call up the Main Menu.

2. While looking through the eyepiece display, rotate the

diopter adjuster until the menu text appears sharp and

clear.