beautypg.com

Overview – Ag Leader ParaDyme Auxiliary Harness Installation User Manual

Page 3

background image

Auxiliary Harness Installation Guide

3

Overview

Overview

This guide describes the installation of the ParaDyme system optional Auxiliary Harness Part Number 201-0433-02. Read this
guide and familiarize yourself with the system before you install and use the Auxiliary Harness.

The ParaDyme system Auxiliary Harness connects the Roof Module to external devices such as a cell phone booster, weather
station or USB thumb drive. The Auxiliary Harness is required for software upgrades using a USB thumb drive or when
servicing the Roof Module.

Figure 1

ParaDyme System Auxiliary Harness (PN: 201-0433-02)

Table 1

ParaDyme System Auxiliary Harness (PN: 201-0433-02)

Note: To connect to “SERIAL A” or “SERIAL B” using a DE-9 connector you must first connect an adapter cable, PN
201-0450-01.

Table 2

ParaDyme System Auxiliary Harness Pin-Outs

Item

ID

Type

Function

1.

RM Aux.

Deutsch DT06-12SB Connects the cable to the ParaDyme Roof Module

2.

USB

USB Female

USB port for software uploads

3.

Serial A

Deutsch DTM04-4P

Serial cable connection for serial device

4.

Serial B

Deutsch DTM04-4P

Serial cable connection for future use

5.

Power Out

Deutsch DT06-2S

12Vdc power for accessories

Item

Connector

Pin 1

Pin 2

Pin 3

Pin 4

3.

Serial A

RS232 Rx

RS232 Tx

RS232 Gnd

RS232 CTS

4.

Serial B

RS232 Rx

RS232 Tx

RS232 Gnd

No connect

5.

Power Out

Power out

Return

1

2

3

4

5