Rom-based diagnostics, Selecting the amp mode, Hot-plug sas and sata hard drive option – HP ProLiant ML570 G4 Server User Manual
Page 54

Hardware options installation 54
7.
Once the memory has been tested, re-enable POST Speed Up for faster system boot, if desired.
ROM-based diagnostics
1.
Power on the server ("
2.
Press the F10 key, when prompted, to enter the System Maintenance menu.
3.
Select Diagnostics.
4.
Run the Memory Diagnostics.
5.
Once the memory has been tested, exit the utility and reboot.
6.
Select the AMP mode ("
Selecting the AMP mode
1.
Upon reboot, press the F9 key, when prompted, to enter RBSU.
2.
Select System Options.
3.
Select Advanced Memory Protection.
4.
Select the desired memory mode.
•
Advanced ECC (hot-add enabled)
•
Advanced ECC (hot-add disabled)
•
Online Spare Memory with Advanced ECC
•
Hot-Plug Mirrored Memory with Advanced ECC
•
Hot-Plug RAID Memory with Advanced ECC
5.
Press the Escape key twice to go back to the main RBSU menu.
6.
Press the F10 key, when prompted, to exit RBSU. The server reboots and tests all memory in the
system.
IMPORTANT: To reconfigure the memory mode after initial setup, you must reboot the system, enter RBSU,
and select the desired AMP mode.
Hot-plug SAS and SATA hard drive option
When adding hard drives to the server, observe the following general guidelines:
•
The system automatically sets all drive numbers.
•
If only one hard drive is used, install it in the bay with the lowest drive number ("
•
Hard drives must be SFF types.
•
Drives should be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.