Update_rib_firmware parameters, Update_rib_firmware runtime errors, Get_fw_version – HP Remote Insight Lights-Out Edition II Board User Manual
Page 157: Get_fw_version parameters, Get_fw_version runtime errors, Get_fw_version return messages, Cation

Scripting, command line, and utility options 157
UPDATE_RIB_FIRMWARE parameters
IMAGE_LOCATION takes the full path file name of the firmware upgrade file.
UPDATE_RIB_FIRMWARE runtime errors
The possible UPDATE_RIB_FIRMWARE error messages include:
•
RIB information is open for read-only access. Write access is required for this operation.
•
Unable to open the firmware image update file.
•
Unable to read the firmware image update file.
•
The firmware upgrade file size is too big.
•
The firmware image file is not valid.
•
A valid firmware image has not been loaded.
•
The flash process could not be started.
•
IMAGE_LOCATION must not be blank.
•
User does not have correct privilege for action. CONFIG_ILO_PRIV required.
GET_FW_VERSION
The GET_FW_VERSION command requests the respective RILOE II firmware information. For this
command to parse correctly, the command must appear within a RIB_INFO command block, and
RIB_INFO MODE must be set to write. The user must have the configure RILOE II privilege to execute this
command.
Example:
GET_FW_VERSION parameters
None
GET_FW_VERSION runtime errors
None
GET_FW_VERSION return messages
The following information is returned within the response:
FIRMWARE_VERSION = <firmware version>